Sampling Hot Acid Without an Open Bottle: the PFA-Lined Closed Sampling Station

In many chemical plants a sample of concentrated acid is still taken by opening two hand valves over a bottle. The operator stands beside hot corrosive liquid, the quantity is whatever happens to come out, and the drips go on the floor. Tech Inc. now builds a station that ends this practice: the PFA-Lined Closed Fixed-Volume Sampling Station (TI-FVS series).
How it works
Flush. Process liquid flows through a PFA-lined chamber and back to the return point, so the chamber holds fresh, representative liquid.
Isolate. The chamber is closed off. It now holds a fixed 250 mL.
Transfer. The contents drain by gravity through a PTFE docking head into a 500 mL PFA bottle, while the displaced vapour is vented to a safe point.
Complete. The valves return to their safe positions and the bottle is removed and carried away in a lidded carrier.
Why it matters
Nothing is open. From the line to the bottle the sample stays inside lined pipe, a docking head and a closed bottle, all within a polypropylene enclosure with a drip tray.
Only fluoropolymer touches the liquid. Chamber, spools and valves are PFA-lined and the docking head is PTFE, which suits hot concentrated sulphuric acid and other liquids that destroy stainless steel.
The quantity is fixed. The chamber volume is measured and certified for each station, so the laboratory receives the same sample every time and the bottle cannot overfill.
Three levels of automation
The manual version has lockable lever handles, colour coding and an engraved sequence plate. The pneumatic version drives spring-return actuators from a four-position step selector and needs no electrical supply. The automatic version runs the whole sequence from a PLC with an HMI, checks valve positions, will not start without a docked bottle and a closed door, and reports to the plant control system.
See the product page and datasheet, or the full range of sampling systems. To discuss your sampling points, write to mail@techincresearch.com or call +1 (289) 622-1032.
Disclaimer: specifications are typical and can change with the configuration, the fluids used, adherence to the operation manual and other conditions. Images are for representation only. Final data are confirmed in the quotation.