Autoclave Gas Charge and Hydrogen Uptake Calculator for Batch Hydrogenation

In a batch hydrogenation the pressure gauge is the reaction monitor. This calculator turns the charge pressure into moles of gas, predicts the pressure after heating, and converts the pressure drop during the reaction into hydrogen consumed and conversion.
How it works
Headspace = reactor volume − liquid charge; moles charged n = P V ÷ (Z R T), with a van der Waals Z.
Heating at constant volume with no reaction: P₂ = n Z R T₂ ÷ V, solved with Z updated at the hot conditions.
Uptake = moles at the hot start − moles at the final pressure; equivalents = uptake ÷ substrate; conversion against the stoichiometry you enter.
Worked example
A 300 mL reactor with 150 mL of solvent charged to 20 bar(g) of hydrogen at 25 °C holds 125 mmol (2.8 NL). At 120 °C the pressure before reaction is 26.8 bar(g). If the gauge ends at 16 bar(g) at 120 °C, 48 mmol of hydrogen were consumed: 0.96 equivalents on 50 mmol of substrate, 96% apparent conversion for a one-equivalent reduction.
Limits
Hydrogen dissolved in the solvent and the thermal expansion of the liquid are ignored; both are small for a 50% fill at moderate pressure, and both over-state the uptake slightly. For kinetics, feed hydrogen from a reservoir through a constant-pressure regulator and log the reservoir pressure instead. Our benchtop stirred high-pressure reactors, standard high-pressure reactor range, batch hydrogenation reactors and shaker hydrogenators are rated at temperature, which is the number that matters here. All Tech Inc. calculators and converters.
Related tools: Space velocity (GHSV, WHSV, LHSV), Gas cylinder contents, Pressure units (gauge/absolute), Electrolyser hydrogen. All 57 calculators and converters.
Write to mail@techincresearch.com or call +1 (289) 622-1032.
Disclaimer: this calculator and article give estimates from simplified, published equations and the values you enter, for general information only and without warranty. They are not engineering, design, safety or regulatory advice and are no substitute for measurement, the equipment or chemical maker's instructions, the applicable standards or the judgement of a qualified engineer. Do not rely on them for safety-critical decisions. Tech Inc. accepts no liability for loss, damage or injury arising from their use. Equipment specifications are typical and may change; results depend on the fluids and conditions, how the equipment is used and operation in line with the operation manual. See our product information disclaimer and terms of use.
Sources
Chemistry LibreTexts, Van der Waals equation of state.
NIST Chemistry WebBook, Hydrogen: fluid properties.