An electrolyser is a current-to-hydrogen converter at a known exchange rate. This calculator applies that rate, adds the voltage to get the energy bill, and sizes the storage cylinder bank behind it.

How it works

  • Faraday: moles of H₂ per second = I × cells × current efficiency ÷ (2 F); 1 A·h gives 0.01865 mol or 0.418 NL of hydrogen.

  • Oxygen and water follow from the stoichiometry 2 H₂O → 2 H₂ + O₂.

  • Specific energy = (stack power + auxiliaries) ÷ hydrogen mass; LHV efficiency = 33.33 kWh/kg ÷ specific energy; voltage efficiency against the 1.48 V thermoneutral voltage.

  • Storage: n = P V ÷ (Z R T) with a van der Waals Z for hydrogen, mass and fill time.

Worked example

500 A through 20 cells at 1.9 V and 98% current efficiency makes 4.1 Nm³/h, 0.37 kg/h, 8.8 kg/day, consuming 3.3 kg/h of water. Stack power is 19 kW; with 2 kW of auxiliaries the specific energy is 57 kWh/kg, 58% on LHV. A 500 L bank at 350 bar(g) and 25 °C holds 11 kg (Z = 1.30), about 30 hours of production.

Limits

Current efficiency falls with crossover at low load and high pressure; cell voltage rises with current density and age, so efficiency is a curve, not a number. Purification, drying and compression energy are in the auxiliary term only if you put them there. For fiscal hydrogen metering use NIST or ISO 6976-style property data rather than van der Waals. Our PEM hydrogen generators, high-pressure lab hydrogen generators, hydrogen component test stands and high-pressure gas storage and distribution skids cover generation to storage; see the green hydrogen electrolyser water and gas treatment process note. All Tech Inc. calculators and converters.

Write to mail@techincresearch.com or call +1 (289) 622-1032.

Disclaimer: this calculator and article give estimates from simplified, published equations and the values you enter, for general information only and without warranty. They are not engineering, design, safety or regulatory advice and are no substitute for measurement, the equipment or chemical maker's instructions, the applicable standards or the judgement of a qualified engineer. Do not rely on them for safety-critical decisions. Tech Inc. accepts no liability for loss, damage or injury arising from their use. Equipment specifications are typical and may change; results depend on the fluids and conditions, how the equipment is used and operation in line with the operation manual. See our product information disclaimer and terms of use.