top of page

Electrowinning Calculator: Faraday Metal Yield, Current Density, kWh per Tonne and Cell Count

Writer: Tech Inc
Tech Inc
1 day ago
2 min read

Electrowinning turns amperes into tonnes at a fixed exchange rate per metal. This calculator gives the yield, the energy cost and the number of cells needed for a target production, from pilot cell to tankhouse.

How it works

  • Faraday: mass = I t M ÷ (z F) × current efficiency, with M and z for the chosen metal.

  • Current density = current ÷ cathode area; deposit thickness from the mass per area and the metal density.

  • Specific energy = V z F ÷ (3.6 M × CE) in kWh/kg; circuit power = I × V × cells.

  • Plant sizing: cells = metal rate needed ÷ metal rate per cell at 330 operating days.

Worked example

5,000 A through 10 copper cells at 2.0 V and 92% efficiency plates 5.45 kg/h per cell, 9.2 t in a week; at 20 m² of cathode per cell the current density is 250 A/m² and the deposit grows 30 µm/h, 5.1 mm in a week. Specific energy 1.83 kWh/kg; 2,000 t/year needs 47 cells and a 470 kW rectifier.

Limits

Current efficiency is the measured variable: it falls with low metal tenor, high iron, poor electrolyte flow and short circuits. Cell voltage includes anode overpotential, electrolyte and contact losses and varies with temperature and current density; measure it on the pilot cell. Our electrowinning cell and rectifier skids, ion exchange metal recovery columns and spent catalyst metal recovery pilot plants are in the battery recycling and hydrometallurgy range. All Tech Inc. calculators and converters.

Write to mail@techincresearch.com or call +1 (289) 622-1032.

Disclaimer: this calculator and article give estimates from simplified, published equations and the values you enter, for general information only and without warranty. They are not engineering, design, safety or regulatory advice and are no substitute for measurement, the equipment or chemical maker's instructions, the applicable standards or the judgement of a qualified engineer. Do not rely on them for safety-critical decisions. Tech Inc. accepts no liability for loss, damage or injury arising from their use. Equipment specifications are typical and may change; results depend on the fluids and conditions, how the equipment is used and operation in line with the operation manual. See our product information disclaimer and terms of use.