Conductivity to TDS Converter with NaCl Equivalent, Ionic Strength and Osmotic Pressure

Membrane test feeds are mixed by weight and checked by conductivity. This converter moves between conductivity, TDS and NaCl concentration, corrects for temperature and adds the ionic strength and osmotic pressure a test report needs.
How it works
Conductivity is corrected to 25 °C at 2% per °C.
TDS = conductivity × factor; 0.64 is common, 0.5 to 0.75 depending on the salts.
NaCl concentration uses a fitted molar conductivity curve, inverted numerically.
Ionic strength and osmotic pressure treat the salt as NaCl.
Worked example
2,000 µS/cm at 25 °C: TDS 1,280 mg/L at factor 0.64, about 1,015 mg/L as NaCl, 0.017 mol/L, 0.86 bar osmotic pressure.
Limits
The NaCl curve is for NaCl; seawater and mixed waters need their own factor. Above about 50 g/L the fit flattens. For rejection calculations use the same basis for feed and permeate; see how to test salt rejection and the RO recovery and rejection calculator. All Tech Inc. calculators and converters.
Related tools: Osmotic pressure, RO recovery and rejection, Water hardness units, SDI calculator. All 57 calculators and converters.
Write to mail@techincresearch.com or call +1 (289) 622-1032.
Disclaimer: this calculator and article give estimates from simplified, published equations and the values you enter, for general information only and without warranty. They are not engineering, design, safety or regulatory advice and are no substitute for measurement, the equipment or chemical maker's instructions, the applicable standards or the judgement of a qualified engineer. Do not rely on them for safety-critical decisions. Tech Inc. accepts no liability for loss, damage or injury arising from their use. Equipment specifications are typical and may change; results depend on the membranes and conditions, how the equipment is used and operation in line with the operation manual. See our product information disclaimer and terms of use.
Sources
Chemistry LibreTexts, Conductivity and molar conductivity of electrolytes.