top of page

SDI Calculator: Silt Density Index from Your Test Times, with the 75% Check

Writer: Tech Inc
Tech Inc
1 day ago
2 min read

Enter the time to collect the first 500 mL (ti), the time to collect 500 mL after the test interval (tf), and the interval itself. The calculator gives SDI and percentage plugging, and warns when plugging is above 75% so the result should not be reported.

How it works

  • %P = (1 − ti ÷ tf) × 100

  • SDI(T) = %P ÷ T, with T in minutes

The test runs at 207 kPa (30 psi) through a 0.45 µm, 47 mm membrane filter, as in ASTM D4189.

Worked example

ti = 28 s, tf = 40 s after 15 minutes: %P = 30%, SDI15 = 2.0. If tf had been 140 s, %P would be 80%: above the limit, so repeat with a 10 or 5 minute interval.

Learn more

Equipment

Write to mail@techincresearch.com or call +1 (289) 622-1032.

Disclaimer: this calculator and article give estimates from simplified, published equations and the values you enter, for general information only and without warranty. They are not engineering, design, safety or regulatory advice and are no substitute for measurement, the equipment or chemical maker's instructions, the applicable standards or the judgement of a qualified engineer. Do not rely on them for safety-critical decisions. Tech Inc. accepts no liability for loss, damage or injury arising from their use. Equipment specifications are typical and may change; results depend on the membranes and conditions, how the equipment is used and operation in line with the operation manual.

Sources

Comments


bottom of page