2 min read

A valve is tested before it ships, and the certificate names one of two standards: ISO 5208, Industrial valves: pressure testing of metallic valves (2015), used worldwide and in EN 12266, or API 598, Valve Inspection and Testing (11th edition), used with API 600, 602, 608, 609 and most North American procurement.

ISO 5208

The standard specifies the tests, test pressures, durations and acceptable leakage for metallic industrial valves. The shell test is at 1.5 times the pressure rating at 20 °C (hydrostatic) or at 1.1 times for the optional gas shell test; the seat (closure) test at 1.1 times the rating, hydrostatic or with low-pressure gas at 6 bar. Durations depend on valve size. The distinguishing feature is the leakage rate scale: Rate A (no visible leakage, for soft seats), Rates B, C and D for metal seats with increasing allowances proportional to size, and further rates, each expressed as drops per minute for liquid or bubbles per minute for gas.

API 598

API 598 covers inspection, examination, supplementary examinations and pressure tests for resilient-seated, non-metallic-seated and metal-seated valves. Shell test at 1.5 times the 38 °C rating, backseat test for gate and globe valves, low-pressure closure test with air or inert gas at 4 to 7 bar, and high-pressure closure test at 1.1 times the rating. Leakage allowances: zero for resilient seats; for metal-seated valves a table of drops or bubbles per minute by size; check valves have their own allowance. Test fluid, temperature and the limit on chloride content in the water for stainless valves are also specified.

Reading a certificate

It should name the standard and edition, the shell and seat test pressures and durations actually applied, the test medium and temperature, the leakage rate or class achieved, the gauge calibration references and the inspector. A "tested OK" line without these is not a test certificate.

Our equipment

Our high-pressure hydrostatic test units and valve test benches perform these tests with calibrated gauges and recorders, and every valve fitted to our skids carries a certificate to one of the two standards; see the API 6D guide for the valve specification itself and the UKAS and ISO/IEC 17025 guide for the gauge calibration behind the test. All our standards guides.

Send your application, materials and the standards your contract names to mail@techincresearch.com or call +1 (289) 622-1032, and we will return a configuration, datasheet and quotation.

This article is our commentary on the standard's published scope, not a substitute for the standard itself; always work to the current edition named in your contract. Equipment specifications may change; performance depends on the application, how the equipment is used and operation in line with the operation manual.