A plate with a hole, two pressure taps and a transmitter can measure flow to better than one percent, but only if it is built, installed and calculated to the standard. That standard is the ISO 5167 series, Measurement of fluid flow by means of pressure differential devices inserted in circular cross-section conduits running full.

The parts

  • Part 1 (2022), General principles and requirements: definitions, the general equation (mass flow from C, ε, d, β, ΔP and density), installation requirements common to all devices, and the uncertainty method.

  • Part 2 (2022), Orifice plates: plate geometry and edge sharpness, the three tapping arrangements (corner, flange, D and D/2), the Reader-Harris/Gallagher equation for the discharge coefficient as a function of β, Reynolds number and tapping geometry, the expansibility factor for gases, the limits of use (50 to 1,000 mm pipe, β 0.10 to 0.75, minimum Reynolds number) and the straight-length and flow-conditioner requirements upstream and downstream.

  • Part 3, Nozzles and Venturi nozzles; Part 4, Venturi tubes; Part 5, Cone meters; Part 6, Wedge meters.

The design points

Upstream straight length depends on β and the upstream fitting, and can exceed 40 diameters without a flow conditioner; plate edge sharpness and flatness degrade with erosion and must be inspected; the pressure transmitter range and the square-root relationship limit practical turndown to about 3:1 or 4:1 per transmitter, which is why metering skids stack transmitters or use multiple runs; and density at flowing conditions needs pressure, temperature and composition or a densitometer. In North America the equivalent for natural gas is AGA Report No. 3 / API MPMS Chapter 14.3, with a different but closely related coefficient equation.

Our equipment

Gas metering skids, pressure reducing and metering stations and the metering and loading skids range are built with orifice runs to this series; the orifice flow meter calculator implements the Part 2 equations and the ISO 13443 and ISO 6976 guide covers the reference conditions for the result. All our standards guides.

Send your application, materials and the standards your contract names to mail@techincresearch.com or call +1 (289) 622-1032, and we will return a configuration, datasheet and quotation.

This article is our commentary on the standard's published scope, not a substitute for the standard itself; always work to the current edition named in your contract. Equipment specifications may change; performance depends on the application, how the equipment is used and operation in line with the operation manual.

Sources

Comments