RO Recovery, Rejection and Concentrate Calculator with Mass Balance Check

Enter feed and permeate flows and concentrations. The calculator returns recovery, rejection, salt passage, concentrate flow and concentration, and the concentration factor. Add a measured concentrate value to check your data against the mass balance.
How it works
Recovery = Qp ÷ Qf
Rejection = 1 − Cp ÷ Cf
Mass balance: Qf × Cf = Qp × Cp + Qc × Cc, so Cc = (Qf Cf − Qp Cp) ÷ Qc
Concentration factor = Cc ÷ Cf, close to 1 ÷ (1 − recovery) when rejection is high
Worked example
100 L/h feed at 2,000 mg/L; 75 L/h permeate at 40 mg/L: recovery 75%, rejection 98%, concentrate 7,880 mg/L, concentration factor 3.94.
If the measured concentrate differs from the balance by more than about 10%, check flow meters, sampling, leaks and scaling.
More: recovery and concentration factor guide and normalised permeate flow. Equipment: CCRO lab test skid and CCRO pilot test skid. All membrane calculators and converters.
Related tools: Osmotic pressure, Concentration polarisation, SDI calculator, Conductivity to TDS. All 57 calculators and converters.
Write to mail@techincresearch.com or call +1 (289) 622-1032.
Disclaimer: this calculator and article give estimates from simplified, published equations and the values you enter, for general information only and without warranty. They are not engineering, design, safety or regulatory advice and are no substitute for measurement, the equipment or chemical maker's instructions, the applicable standards or the judgement of a qualified engineer. Do not rely on them for safety-critical decisions. Tech Inc. accepts no liability for loss, damage or injury arising from their use. Equipment specifications are typical and may change; results depend on the membranes and conditions, how the equipment is used and operation in line with the operation manual.
Sources
ASTM International, ASTM D4516-19a Standard Practice for Standardizing Reverse Osmosis Performance Data.





Comments