top of page

Concentration Polarisation Calculator: Polarisation Factor and True Rejection

Writer: Tech Inc
Tech Inc
1 day ago
2 min read

Enter flux, the mass transfer coefficient of your cell, and the feed and permeate concentrations. The calculator gives the polarisation factor, the concentration at the membrane surface, and both observed and intrinsic (true) rejection.

How it works

  • Film model: Cm ÷ Cb = exp(J ÷ k)

  • Observed rejection = 1 − Cp ÷ Cb

  • Intrinsic rejection = 1 − Cp ÷ Cm

The mass transfer coefficient k depends on crossflow velocity and channel design; it is usually estimated from correlations or measured for a given cell.

Worked example

20 LMH with k = 20 µm/s gives a polarisation factor of 1.32. With 2,000 mg/L feed and 40 mg/L permeate, observed rejection is 98.0% and intrinsic rejection 98.5%.

Write to mail@techincresearch.com or call +1 (289) 622-1032.

Disclaimer: this calculator and article give estimates from simplified, published equations and the values you enter, for general information only and without warranty. They are not engineering, design, safety or regulatory advice and are no substitute for measurement, the equipment or chemical maker's instructions, the applicable standards or the judgement of a qualified engineer. Do not rely on them for safety-critical decisions. Tech Inc. accepts no liability for loss, damage or injury arising from their use. Equipment specifications are typical and may change; results depend on the membranes and conditions, how the equipment is used and operation in line with the operation manual.

Sources

Comments