top of page

Dew Point to ppm Converter: Water Dew Point, ppmv, lb/MMscf and mg/Nm³ at Line Pressure

Writer: Tech Inc
Tech Inc
1 day ago
2 min read

A dew point of −40 °C means a different water content at 1 bar and at 70 bar, and a moisture analyser reads ppmv while a gas contract says lb/MMscf. This converter joins them at the pressure you specify.

How it works

Saturation vapour pressure of water over ice (below 0 °C) or water from the Buck 1996 equations; mole fraction = vapour pressure ÷ total pressure (ideal mixing). ppmv, ppmw (with the carrier molecular weight), lb/MMscf at 60 °F and 14.696 psia (379.48 scf per lbmol) and mg/Nm³ follow; dew points at other pressures come from inverting the same relation.

Worked example

A −40 °C dew point at 7 bar(g) in natural gas is 16 ppmv, 0.76 lb/MMscf, 12.9 mg/Nm³, 16.5 ppmw; the same gas has a dew point of −57 °C at atmospheric pressure and −19 °C at 70 bar, which is why pipeline specifications quote the pressure.

Limits

Real gases hold more water than ideal mixing predicts, by 10 to 20% at 70 bar in natural gas (the enhancement factor); for custody transfer use GPA 2172 / ISO 18453 data. Hydrate formation temperature is a separate calculation from water dew point. Our H₂S and moisture analyser sampling cabinets, gas dehydration skids, CO₂ dehydration units and high-pressure gas filter dryers are specified with these figures; see the CCUS CO₂ conditioning and dehydration process note. All Tech Inc. calculators and converters.

Write to mail@techincresearch.com or call +1 (289) 622-1032.

Disclaimer: this calculator and article give estimates from simplified, published equations and the values you enter, for general information only and without warranty. They are not engineering, design, safety or regulatory advice and are no substitute for measurement, the equipment or chemical maker's instructions, the applicable standards or the judgement of a qualified engineer. Do not rely on them for safety-critical decisions. Tech Inc. accepts no liability for loss, damage or injury arising from their use. Equipment specifications are typical and may change; results depend on the fluids and conditions, how the equipment is used and operation in line with the operation manual. See our product information disclaimer and terms of use.

Sources