Membrane Distillation Calculator: Vapour Pressure Driving Force and Flux

Membrane distillation runs on a vapour pressure difference, not a hydraulic one. This calculator finds that difference for your temperatures and salinity, and turns it into flux once you know the membrane coefficient.
How it works
Water vapour pressure from the Antoine equation (valid 1 to 100 °C).
Feed activity by Raoult's law with i = 2 for NaCl, which lowers the feed vapour pressure.
Flux J = Bm × Δp. Find Bm from a pure-water run on the same membrane: Bm = J ÷ Δp.
Worked example
60 °C feed at 35 g/L against a 20 °C cold side: Δp = 17.1 kPa (0.43 kPa lost to salinity). With Bm = 1.5 kg/m²·h·kPa the flux is about 26 LMH.
Limits
Temperature polarisation reduces the real driving force, so measured flux is lower; the gap tells you how good your flow channels are. Our MD test skids and MD cells record the temperatures this needs. More in membrane distillation for brine and ZLD. All Tech Inc. calculators and converters.
Related tools: Pervaporation, Osmotic pressure, Forward osmosis flux, Dew point and moisture. All 57 calculators and converters.
Write to mail@techincresearch.com or call +1 (289) 622-1032.
Disclaimer: this calculator and article give estimates from simplified, published equations and the values you enter, for general information only and without warranty. They are not engineering, design, safety or regulatory advice and are no substitute for measurement, the equipment or chemical maker's instructions, the applicable standards or the judgement of a qualified engineer. Do not rely on them for safety-critical decisions. Tech Inc. accepts no liability for loss, damage or injury arising from their use. Equipment specifications are typical and may change; results depend on the membranes and conditions, how the equipment is used and operation in line with the operation manual. See our product information disclaimer and terms of use.
Sources
NIST Chemistry WebBook, Water: Antoine equation parameters.