top of page

Pervaporation Calculator: Flux, Separation Factor and PSI

Writer: Tech Inc
Tech Inc
1 day ago
2 min read

Enter the mass of permeate collected in the cold trap, the membrane area and collection time, and the share of the faster-permeating component in feed and permeate. The calculator returns flux, separation factor, enrichment factor and PSI.

How it works

  • Flux, J = m ÷ (A × t)

  • Separation factor, α = (y ÷ (1 − y)) ÷ (x ÷ (1 − x)), with y and x the permeate and feed fractions of the faster component

  • PSI = J × (α − 1); some authors report J × α, so the calculator shows both

Worked example

12 g in 2 hours through 20 cm², feed 10% water, permeate 90% water: flux 3.0 kg/(m²·h), α = 81, PSI = 240 kg/(m²·h).

Write to mail@techincresearch.com or call +1 (289) 622-1032.

Disclaimer: this calculator and article give estimates from simplified, published equations and the values you enter, for general information only and without warranty. They are not engineering, design, safety or regulatory advice and are no substitute for measurement, the equipment or chemical maker's instructions, the applicable standards or the judgement of a qualified engineer. Do not rely on them for safety-critical decisions. Tech Inc. accepts no liability for loss, damage or injury arising from their use. Equipment specifications are typical and may change; results depend on the membranes and conditions, how the equipment is used and operation in line with the operation manual.

Sources

Comments


bottom of page