top of page

Gas Permeance and Permeability Converter: GPU, Barrer and SI Units

Writer: Tech Inc
Tech Inc
1 day ago
2 min read

Gas separation papers mix GPU, Barrer and SI units. This converter handles the three conversions you need most often.

The units

  • GPU (gas permeation unit), for permeance: 1 GPU = 10⁻⁶ cm³(STP)/(cm²·s·cmHg) ≈ 3.348 × 10⁻¹⁰ mol/(m²·s·Pa).

  • Barrer, for permeability: 1 Barrer = 10⁻¹⁰ cm³(STP)·cm/(cm²·s·cmHg) ≈ 3.35 × 10⁻¹⁶ mol·m/(m²·s·Pa).

  • Permeance = permeability ÷ thickness. With thickness in micrometres, permeance in GPU = permeability in Barrer ÷ thickness in µm.

  • Ideal selectivity = permeance (or permeability) of gas A ÷ that of gas B.

Worked example

A polymer with a CO2 permeability of 100 Barrer, as a 0.1 µm selective layer, gives a CO2 permeance of 1,000 GPU (3.35 × 10⁻⁷ mol/(m²·s·Pa)). If N2 permeance is 40 GPU, the ideal CO2/N2 selectivity is 25.

Write to mail@techincresearch.com or call +1 (289) 622-1032.

Disclaimer: this calculator and article give estimates from simplified, published equations and the values you enter, for general information only and without warranty. They are not engineering, design, safety or regulatory advice and are no substitute for measurement, the equipment or chemical maker's instructions, the applicable standards or the judgement of a qualified engineer. Do not rely on them for safety-critical decisions. Tech Inc. accepts no liability for loss, damage or injury arising from their use. Equipment specifications are typical and may change; results depend on the membranes and conditions, how the equipment is used and operation in line with the operation manual.

Sources

Comments


bottom of page