Gas Flow Unit Converter: Nm³/h, Sm³/h, SCFM, SLPM, MMscfd, kg/h and Actual Flow

Nm³/h, Sm³/h and SCFM differ by up to 7% because "standard" has four definitions. This converter states each reference, converts through molar flow and gives the mass flow, which is the one figure everybody agrees on.
How it works
Molar flow n = P_ref V ÷ (R T_ref) for the chosen reference; every other standard unit is n R T_ref ÷ P_ref at its own reference. Mass flow = n × molecular weight. Actual flow at line conditions uses Z from van der Waals (or the Z you enter) and the pressure and temperature you give.
Worked example
100 Nm³/h of nitrogen is 105.5 Sm³/h (15 °C), 62.2 SCFM (60 °F), 1,667 SLPM at 0 °C or 1,789 SLPM at 20 °C, and 125 kg/h. At 7 bar(g) and 40 °C it occupies 14.4 m³/h actual, 8.5 ACFM.
Limits
Mass flow controllers and rotameters each have their own calibration reference; check the datasheet before converting. Natural gas composition changes the molecular weight; the typical value here (17.5) is for a lean pipeline gas. Our gas metering skids, pressure reducing and metering stations and calibration gas blending panels are specified on these bases; the gas cylinder contents calculator is the companion. All Tech Inc. calculators and converters.
Related tools: Gas cylinder contents, Gas concentration (ppm, mg/Nm³), Sample line lag time, Space velocity (GHSV, WHSV, LHSV). All 57 calculators and converters.
Write to mail@techincresearch.com or call +1 (289) 622-1032.
Disclaimer: this calculator and article give estimates from simplified, published equations and the values you enter, for general information only and without warranty. They are not engineering, design, safety or regulatory advice and are no substitute for measurement, the equipment or chemical maker's instructions, the applicable standards or the judgement of a qualified engineer. Do not rely on them for safety-critical decisions. Tech Inc. accepts no liability for loss, damage or injury arising from their use. Equipment specifications are typical and may change; results depend on the fluids and conditions, how the equipment is used and operation in line with the operation manual. See our product information disclaimer and terms of use.
Sources
Engineering ToolBox, Standard and normal cubic metre: SCFM and Nm³/h.