top of page

Gas Cylinder Contents Calculator: Standard Volume, Mass and Run Time from Pressure

Writer: Tech Inc
Tech Inc
1 day ago
2 min read

How long will the nitrogen last? Cylinder contents are rated at a nominal pressure and temperature; the real amount depends on the actual pressure, the temperature and, above 100 bar, the compressibility of the gas. This calculator does the arithmetic with a van der Waals correction.

How it works

  • Moles n = P V ÷ (Z R T) with absolute pressure and the compressibility Z from the van der Waals equation for the chosen gas.

  • Standard volume at 0 °C and 1.01325 bar (Nm³) and at 60 °F and 14.696 psia (scf).

  • Usable volume is the content above the residual pressure you keep in the cylinder; run time = usable ÷ draw-off flow.

Worked example

A 50 L cylinder of nitrogen at 200 bar(g) and 20 °C holds 411 mol, 9.2 Nm³, 11.5 kg. Keeping 10 bar(g) residual and drawing 2 L/min at standard conditions, it lasts about 72 hours, three days.

Limits

Van der Waals is within a few percent for permanent gases to about 300 bar; hydrogen and helium are slightly over-estimated at the highest pressures. Liquefied gases (CO₂, propane, ammonia, SO₂) are not on the list on purpose: their pressure says nothing about the contents, which must be weighed. Our laboratory specialty gas panels, gas distribution systems, automatic gas changeover manifolds and analyser purge and calibration gas panels keep the supply steady between changeovers. See also the gas flow unit converter. All Tech Inc. calculators and converters.

Write to mail@techincresearch.com or call +1 (289) 622-1032.

Disclaimer: this calculator and article give estimates from simplified, published equations and the values you enter, for general information only and without warranty. They are not engineering, design, safety or regulatory advice and are no substitute for measurement, the equipment or chemical maker's instructions, the applicable standards or the judgement of a qualified engineer. Do not rely on them for safety-critical decisions. Tech Inc. accepts no liability for loss, damage or injury arising from their use. Equipment specifications are typical and may change; results depend on the fluids and conditions, how the equipment is used and operation in line with the operation manual. See our product information disclaimer and terms of use.

Sources