top of page

Sample Line Lag Time Calculator: Transport Delay and Purge Time for Analyser Sample Lines

Writer: Tech Inc
Tech Inc
1 day ago
2 min read

An analyser can only be as fast as the line that feeds it. This calculator gives the transport lag and the purge time for your tubing, flow and pressure, so the sample system is designed around the response time the process needs.

How it works

  • Internal volume = π/4 × ID² × length + dead volume of filters, coolers and fittings.

  • Gas flows quoted at standard conditions are converted to actual volume at line pressure and temperature; the lag is volume ÷ actual flow.

  • Purge time = lag × number of volumes. Three to five volumes are the usual minimum before a grab sample; ten for trace work.

Worked example

30 m of 1/4" tubing (4.57 mm ID) with 50 mL of dead volume holds 542 mL. At 10 bar(g) a 1 L/min standard flow is only 0.1 L/min actual, so the lag is 5.4 minutes and a five-volume purge 27 minutes. The same line at atmospheric pressure, or with a fast loop running at 5 L/min, brings the lag to seconds.

Limits

Mixing in the line stretches the response beyond the plug-flow lag; keep velocities above 0.5 m/s for liquids and avoid dead legs. Pressure reduction should be at the tap, not at the analyser, so the line runs at low pressure and small volume. Our sample conditioning systems, fast-loop automatic sampling systems, modular sample system modules and GC sampling cabinets are designed around these numbers. See also instrument tubing pressure drop. All Tech Inc. calculators and converters.

Write to mail@techincresearch.com or call +1 (289) 622-1032.

Disclaimer: this calculator and article give estimates from simplified, published equations and the values you enter, for general information only and without warranty. They are not engineering, design, safety or regulatory advice and are no substitute for measurement, the equipment or chemical maker's instructions, the applicable standards or the judgement of a qualified engineer. Do not rely on them for safety-critical decisions. Tech Inc. accepts no liability for loss, damage or injury arising from their use. Equipment specifications are typical and may change; results depend on the fluids and conditions, how the equipment is used and operation in line with the operation manual. See our product information disclaimer and terms of use.

Sources

Comments