top of page

Instrument Tubing Pressure Drop Calculator for Sample Lines and Impulse Lines

Writer: Tech Inc
Tech Inc
1 day ago
2 min read

Sample lines and impulse lines are small-bore, and small bores lose pressure fast. This calculator gives the drop for standard instrument tubing sizes so the fast loop, the analyser supply or the sample return is checked before the panel is built.

How it works

  • Darcy–Weisbach: ΔP = f × (L ÷ D) × ρ u² ÷ 2, with fittings added as equivalent length.

  • Friction factor from the Churchill equation, which covers laminar, transitional and turbulent flow in one expression, with the tube roughness you enter.

  • Gases: density at the inlet pressure and temperature; the result is reliable while the drop is below about 10% of the inlet pressure, and the tool warns beyond that. Standard-condition gas flows are converted to actual flow first.

Worked example

20 m of 3/8" × 0.035" tubing (7.75 mm ID) plus 5 m of fittings carrying 2 L/min of water: velocity 0.71 m/s, Reynolds 5,500, friction factor 0.037 and a drop of 0.30 bar (4.3 psi). The same flow in 1/4" tubing would lose about 2.6 bar.

Limits

Two-phase flow, flashing liquids and long gas lines with large drops need a compressible-flow calculation. Keep liquid velocities under 3 m/s and sample lines short; where the run is long, a fast loop with a return to a lower-pressure point is the standard answer. Our gas sampling panels, enclosed manual sampling panels and analyser shelters and sample conditioning systems are laid out with these numbers. See also sample line lag time. All Tech Inc. calculators and converters.

Write to mail@techincresearch.com or call +1 (289) 622-1032.

Disclaimer: this calculator and article give estimates from simplified, published equations and the values you enter, for general information only and without warranty. They are not engineering, design, safety or regulatory advice and are no substitute for measurement, the equipment or chemical maker's instructions, the applicable standards or the judgement of a qualified engineer. Do not rely on them for safety-critical decisions. Tech Inc. accepts no liability for loss, damage or injury arising from their use. Equipment specifications are typical and may change; results depend on the fluids and conditions, how the equipment is used and operation in line with the operation manual. See our product information disclaimer and terms of use.

Sources

Comments