Viscosity Unit Converter: cSt, cP, mm²/s, Pa·s, SUS, Poise and Reyn

Centistokes and centipoise are the same number only for water. This converter keeps kinematic and dynamic viscosity apart, links them through density, and includes the Saybolt seconds still found on older lubricant and fuel specifications.
How it works
Kinematic units convert directly (1 cSt = 1 mm²/s = 10⁻⁶ m²/s); dynamic = kinematic × density. SUS at 100 °F from ASTM D2161: 4.6324 ν + (1 + 0.03264 ν) ÷ [(3930.2 + 262.7 ν + 23.97 ν² + 1.646 ν³) × 10⁻⁵], valid above 1.8 cSt; at other temperatures SUS is scaled by 1 + 0.000061 (t°F − 100). SUS to cSt is solved numerically.
Worked example
46 cSt at 870 kg/m³ is 40.0 cP (mPa·s), 0.040 Pa·s, 0.40 poise, 214 SUS at 100 °F and 5.8 × 10⁻⁶ reyn, and corresponds to ISO VG 46 if measured at 40 °C.
Limits
Density must be at the same temperature as the viscosity for the kinematic–dynamic link. Redwood and Engler seconds are not included because their conversions are approximate and instrument-specific. Viscosity at other temperatures is the job of the lube oil viscosity calculator. Our lube oil consoles, lube oil blending skids and heated lube oil flushing skids are in the lubrication stations range. All Tech Inc. calculators and converters.
Related tools: Lube oil viscosity and VI, Tubing pressure drop, Flux temperature correction, ISO 4406 code and beta ratio. All 57 calculators and converters.
Write to mail@techincresearch.com or call +1 (289) 622-1032.
Disclaimer: this calculator and article give estimates from simplified, published equations and the values you enter, for general information only and without warranty. They are not engineering, design, safety or regulatory advice and are no substitute for measurement, the equipment or chemical maker's instructions, the applicable standards or the judgement of a qualified engineer. Do not rely on them for safety-critical decisions. Tech Inc. accepts no liability for loss, damage or injury arising from their use. Equipment specifications are typical and may change; results depend on the fluids and conditions, how the equipment is used and operation in line with the operation manual. See our product information disclaimer and terms of use.
Sources
ASTM International, ASTM D2161 Standard Practice for Conversion of Kinematic Viscosity to Saybolt Universal Viscosity or to Saybolt Furol Viscosity.
Engineering ToolBox, Dynamic, absolute and kinematic viscosity.