top of page

Lube Oil Viscosity Calculator: Viscosity at Any Temperature (ASTM D341), Viscosity Index and Blending

Writer: Tech Inc
Tech Inc
1 day ago
2 min read

Lubricant datasheets give viscosity at 40 and 100 °C; bearings, pumps and filters run somewhere else. This calculator interpolates and extrapolates on the ASTM D341 chart, reports the viscosity index and estimates the viscosity of a blend of two oils.

How it works

  • ASTM D341 (Walther): log log(ν + 0.7) = A − B log T with T in kelvin; two points fix A and B, and the viscosity at any temperature follows.

  • Dynamic viscosity = kinematic × density, with density corrected from 15 °C at 0.65 kg/m³ per °C.

  • Viscosity index per ASTM D2270 from the 40 and 100 °C viscosities and the reference values L and H; the equations for L and H apply at or above 70 cSt at 100 °C, and for lighter oils you enter L and H from the standard's table.

  • Blending by the Refutas method on viscosity blending numbers and mass fractions.

Worked example

An ISO VG 46 oil (46 cSt at 40 °C, 6.8 at 100 °C) has 20.6 cSt at 60 °C and, at 841 kg/m³, a dynamic viscosity of 17.3 mPa·s. Blending it 70:30 by mass with an ISO VG 220 oil gives about 70 cSt at 40 °C, an ISO VG 68.

Limits

D341 is for Newtonian oils above about 2 cSt; polymer-thickened multigrades shear-thin and deviate at low temperature. Refutas estimates are typically within 5 to 10%; verify blends with a viscometer before release. Our lube oil blending skids, lube additive dosing skids and lube filtration and filling skids are the production side of this calculation; see also the viscosity unit converter. All Tech Inc. calculators and converters.

Write to mail@techincresearch.com or call +1 (289) 622-1032.

Disclaimer: this calculator and article give estimates from simplified, published equations and the values you enter, for general information only and without warranty. They are not engineering, design, safety or regulatory advice and are no substitute for measurement, the equipment or chemical maker's instructions, the applicable standards or the judgement of a qualified engineer. Do not rely on them for safety-critical decisions. Tech Inc. accepts no liability for loss, damage or injury arising from their use. Equipment specifications are typical and may change; results depend on the fluids and conditions, how the equipment is used and operation in line with the operation manual. See our product information disclaimer and terms of use.

Sources

Comments