top of page

ISO 4406 Cleanliness Code Calculator and Filter Beta Ratio Calculator

Writer: Tech Inc
Tech Inc
1 day ago
2 min read

A hydraulic or lube oil report says 18/16/13; a filter datasheet says β₁₀(c) ≥ 1000. This calculator produces both from raw particle counts and explains what they mean.

How it works

  • ISO 4406: each scale number covers a factor-of-two range of particles per mL; the code lists the scale numbers for particles ≥ 4, ≥ 6 and ≥ 14 µm(c) counted by an automatic particle counter calibrated to ISO 11171.

  • Beta ratio (ISO 16889 multipass test): β_x = upstream count ÷ downstream count at size x; efficiency = (1 − 1/β) × 100.

Worked example

Counts of 2,500, 640 and 80 per mL at 4, 6 and 14 µm(c) give code 18/16/13, a typical target for piston pumps. A filter with 10,000 particles ≥ 10 µm(c) upstream and 5 downstream has β₁₀(c) = 2,000, 99.95% capture: absolute-rated.

Limits

Bottle sampling, dilution and water in oil all shift counts; take samples from a turbulent live line into clean bottles. β ratios are test-bench values at a stated terminal pressure drop and do not describe performance after a cold start or under flow surges. Our lube oil filter test bench, filter flow and pressure drop test bench and filter element collapse and burst test bench run the ISO 16889, ISO 3968 and ISO 2941 tests behind these ratings; hydraulic oil dehydrators and fine filtration and mobile oil filtration carts are how the code is improved in service. All Tech Inc. calculators and converters.

Write to mail@techincresearch.com or call +1 (289) 622-1032.

Disclaimer: this calculator and article give estimates from simplified, published equations and the values you enter, for general information only and without warranty. They are not engineering, design, safety or regulatory advice and are no substitute for measurement, the equipment or chemical maker's instructions, the applicable standards or the judgement of a qualified engineer. Do not rely on them for safety-critical decisions. Tech Inc. accepts no liability for loss, damage or injury arising from their use. Equipment specifications are typical and may change; results depend on the fluids and conditions, how the equipment is used and operation in line with the operation manual. See our product information disclaimer and terms of use.

Sources

Comments