top of page

Membrane Flux Temperature Correction Calculator: Normalise Flux to 20 or 25 °C

Writer: Tech Inc
Tech Inc
1 day ago
2 min read

Water passes a membrane faster when it is warm because its viscosity falls. To compare flux measured on different days, correct it to a reference temperature. Enter the measured flux and water temperature and choose 20 or 25 °C.

How it works

J(ref) = J × μ(T) ÷ μ(T(ref))

Water viscosity comes from the empirical equation μ = 2.414 × 10⁻⁵ × 10^(247.8 ÷ (T − 140)) Pa·s, with T in kelvin, which is accurate to within about 2.5% from 0 to 370 °C.

Worked example

50 LMH measured at 15 °C: viscosity is 1.136 mPa·s at 15 °C and 0.890 mPa·s at 25 °C, so the flux at 25 °C is about 63.8 LMH.

When to use the maker's factor instead

This viscosity method suits MF and UF and pure-water tests. For RO and NF elements, membrane makers publish their own temperature correction factors, which also account for changes in the membrane; use those for warranty or design work.

Write to mail@techincresearch.com or call +1 (289) 622-1032.

Disclaimer: this calculator and article give estimates from simplified, published equations and the values you enter, for general information only and without warranty. They are not engineering, design, safety or regulatory advice and are no substitute for measurement, the equipment or chemical maker's instructions, the applicable standards or the judgement of a qualified engineer. Do not rely on them for safety-critical decisions. Tech Inc. accepts no liability for loss, damage or injury arising from their use. Equipment specifications are typical and may change; results depend on the membranes and conditions, how the equipment is used and operation in line with the operation manual.