Membrane Flux and Permeability Calculator: LMH, GFD and LMH/bar

Enter the permeate volume you collected, how long it took, the membrane area and the transmembrane pressure. The calculator gives flux and permeability in the units used in papers, datasheets and plant reports.
How it works
Flux, J = V ÷ (A × t): litres per square metre per hour (LMH). 1 GFD (US gallon per square foot per day) is about 1.70 LMH.
Permeability = J ÷ TMP: LMH/bar, or GFD/psi.
Worked example
50 mL collected in 10 minutes through a 42 cm² coupon at 15 bar:
J = 0.050 L ÷ (0.0042 m² × 0.1667 h) = 71.4 LMH (42.1 GFD)
Permeability = 71.4 ÷ 15 = 4.76 LMH/bar
Tips
Correct flux to a reference temperature before comparing membranes; use the flux temperature correction calculator.
Use the effective (wetted) area of the cell, not the coupon size.
More detail: flux and permeability formulas. Equipment: crossflow test cells and the Automated Clean Water Flux QC Tester. All membrane calculators and converters.
Related tools: Flux temperature correction, Membrane unit converter, Normalised water permeability, Flux recovery and fouling resistance. All 57 calculators and converters.
Write to mail@techincresearch.com or call +1 (289) 622-1032.
Disclaimer: this calculator and article give estimates from simplified, published equations and the values you enter, for general information only and without warranty. They are not engineering, design, safety or regulatory advice and are no substitute for measurement, the equipment or chemical maker's instructions, the applicable standards or the judgement of a qualified engineer. Do not rely on them for safety-critical decisions. Tech Inc. accepts no liability for loss, damage or injury arising from their use. Equipment specifications are typical and may change; results depend on the membranes and conditions, how the equipment is used and operation in line with the operation manual.