top of page

Permeability Unit Converter: Darcy, Millidarcy, m², µm² and Hydraulic Conductivity

Writer: Tech Inc
Tech Inc
1 day ago
2 min read

Reservoir engineers speak millidarcy, membrane and soil scientists speak m² and m/s. This converter moves between them and makes the fluid dependence of hydraulic conductivity explicit.

How it works

1 darcy = 9.869233 × 10⁻¹³ m² (the permeability that passes 1 cm³/s of a 1 cP fluid through 1 cm² under 1 atm/cm). Hydraulic conductivity K = k ρ g ÷ μ uses the water viscosity and density at the temperature you enter, so the same rock has a different K at 5 °C and 40 °C.

Worked example

100 mD = 0.1 darcy = 9.87 × 10⁻¹⁴ m² = 0.0987 µm². For water at 20 °C that is a hydraulic conductivity of 9.6 × 10⁻⁷ m/s, 0.083 m/day, 2.0 US gal/day·ft².

Limits

Permeability is an intrinsic property only for single-phase, non-reactive flow; relative permeability, slip (Klinkenberg) and stress sensitivity are separate corrections, which the core permeability and porosity calculator handles. Our core holders, core flooding systems and core saturators are in the core analysis instruments range. All Tech Inc. calculators and converters.

Write to mail@techincresearch.com or call +1 (289) 622-1032.

Disclaimer: this calculator and article give estimates from simplified, published equations and the values you enter, for general information only and without warranty. They are not engineering, design, safety or regulatory advice and are no substitute for measurement, the equipment or chemical maker's instructions, the applicable standards or the judgement of a qualified engineer. Do not rely on them for safety-critical decisions. Tech Inc. accepts no liability for loss, damage or injury arising from their use. Equipment specifications are typical and may change; results depend on the fluids and conditions, how the equipment is used and operation in line with the operation manual. See our product information disclaimer and terms of use.

Sources

Comments


bottom of page