top of page

Hagen–Poiseuille Pore Flux Calculator: Flux from Pore Size, or Pore Size from Flux

Writer: Tech Inc
Tech Inc
1 day ago
2 min read

For a porous membrane with cylindrical pores, flux follows Hagen–Poiseuille. This calculator runs the equation both ways: predict flux from structure, or estimate pore size from a flux test.

How it works

J = ε r² ΔP ÷ (8 μ τ l). Flux rises with the square of pore radius and falls with thickness and tortuosity; the thickness that matters is the selective layer, not the support.

Worked example

100 nm pores, 10% surface porosity, 1 µm skin, τ 1.5, 1 bar at 25 °C: about 8,400 LMH, i.e. a very open MF skin. Halve the pore size and flux drops four times.

Limits

Real membranes have a pore size distribution, and the mean from a flux is weighted towards the largest pores. Use it to sanity-check porometry and SEM figures, not to replace them. See the bubble point calculator and porosity calculator. All Tech Inc. calculators and converters.

Write to mail@techincresearch.com or call +1 (289) 622-1032.

Disclaimer: this calculator and article give estimates from simplified, published equations and the values you enter, for general information only and without warranty. They are not engineering, design, safety or regulatory advice and are no substitute for measurement, the equipment or chemical maker's instructions, the applicable standards or the judgement of a qualified engineer. Do not rely on them for safety-critical decisions. Tech Inc. accepts no liability for loss, damage or injury arising from their use. Equipment specifications are typical and may change; results depend on the membranes and conditions, how the equipment is used and operation in line with the operation manual. See our product information disclaimer and terms of use.

Sources

Comments