Pervaporation separates liquid mixtures through a dense membrane, with the permeate drawn off as vapour under vacuum and condensed in a cold trap. If you are new to it, start with what pervaporation is. This guide covers the three numbers used to judge a membrane.

1. Flux

J = m ÷ (A × t)

  • m: mass of permeate collected in the cold trap.

  • A: effective membrane area.

  • t: collection time.

2. Separation factor

For a binary mixture of A (the faster component) and B:

α = (yA ÷ yB) ÷ (xA ÷ xB)

where y is the permeate composition and x the feed composition, as mass or mole fractions (state which).

3. Pervaporation separation index

PSI = J × (α − 1)

PSI combines flux and selectivity in one figure. A 2021 review lists both J × α and J × (α − 1) in use, so always state which form you report.

Worked example: ethanol dehydration (illustrative numbers)

  • Feed: 10 wt% water, 90 wt% ethanol.

  • Membrane area: 20 cm² (0.0020 m²).

  • Permeate collected: 12.0 g in 2 hours; analysed at 90 wt% water.

Flux: J = 0.012 kg ÷ (0.0020 m² × 2 h) = 3.0 kg/(m²·h)

Separation factor: α = (0.90 ÷ 0.10) ÷ (0.10 ÷ 0.90) = 81

PSI = 3.0 × (81 − 1) = 240 kg/(m²·h)

Testing tips

  • Steady state first. Discard the first collection; the membrane swells and the cold trap equilibrates.

  • Weigh the trap, not just the liquid. Some permeate freezes on the trap walls.

  • Control temperature. Flux rises sharply with feed temperature; report it.

  • Watch the feed composition. In small batch tests the feed changes as water leaves; keep runs short or top up.

  • Analyse with the right method: water by Karl Fischer titration, organics by gas chromatography or refractive index.