Reid vapour pressure is a test result at 100 °F; the true vapour pressure at the tank, the loading arm or the sample point is what decides flashing, emissions and whether a sample can be taken at atmospheric pressure. This calculator converts one to the other with the correlations used in the US EPA's AP-42 emission estimates.

How it works

TVP = exp(A − B ÷ T), T in degrees Rankine. For refined stocks A and B depend on the RVP and on the ASTM D86 distillation slope S at 10% evaporated: A = 15.64 − 1.854√S − (0.8742 − 0.3280√S) ln RVP and B = 8742 − 1042√S − (1049 − 179.4√S) ln RVP. For crude oil A = 12.82 − 0.9672 ln RVP and B = 7261 − 1216 ln RVP. The table shows the TVP from 0 to 50 °C so the flash risk at each step of handling is visible.

Worked example

A 10 psi RVP gasoline (slope 3.0) at 25 °C has a TVP of 7.1 psia, below atmospheric, so a tank breathes rather than boils; at 50 °C it reaches 15.2 psia and the liquid would flash at atmospheric pressure. At 37.8 °C (100 °F) the TVP is 10.7 psia, close to the RVP as expected.

Limits

The refined-stock correlation is valid for RVP 1 to 20 psi, crude oil 2 to 15 psi. RVP by ASTM D323 includes dissolved air and water; the newer ASTM D5191 mini-method reports a dry vapour pressure equivalent that differs slightly. For live crude and NGL, sample under pressure in a floating-piston cylinder so the light ends are not lost before the test. Our RVP sampling cylinders and constant-pressure sample cylinders are built for that; see the sampling systems range. All Tech Inc. calculators and converters.

Write to mail@techincresearch.com or call +1 (289) 622-1032.

Disclaimer: this calculator and article give estimates from simplified, published equations and the values you enter, for general information only and without warranty. They are not engineering, design, safety or regulatory advice and are no substitute for measurement, the equipment or chemical maker's instructions, the applicable standards or the judgement of a qualified engineer. Do not rely on them for safety-critical decisions. Tech Inc. accepts no liability for loss, damage or injury arising from their use. Equipment specifications are typical and may change; results depend on the fluids and conditions, how the equipment is used and operation in line with the operation manual. See our product information disclaimer and terms of use.