Process Note: CO2 Conditioning, Dehydration and Quality Control for CCUS

At a glance. Carbon capture, utilisation and storage (CCUS) only works if the captured CO2 can be moved safely to storage or use. CO2 from amine capture leaves the stripper saturated with water and carrying traces of oxygen, nitrogen, amine and other gases. Free water and CO2 form carbonic acid, which corrodes carbon steel, and wet CO2 can form hydrates. So the gas is compressed, dried and checked against the transport specification. CCUS projects across the world, in Europe, North America, the Middle East and Asia, set these limits for each pipeline, ship and storage site.
The conditioning steps
Capture outlet. CO2 leaves the amine stripper, or another capture process, at low pressure, warm and wet.
Compression with interstage cooling. Multistage compressors raise the pressure, and coolers and knock-out drums remove condensed water between stages.
Dehydration. Triethylene glycol (TEG) contactors or molecular sieve adsorbers reduce the water content to the specification, often a few tens of parts per million by volume for pipelines and ships.
Impurity removal where needed. Catalytic oxygen removal, sulphur removal or cryogenic purification, for example for ship transport or food-grade use.
Final compression or liquefaction. To dense phase for pipelines, or to a cold liquid for ships.
Metering and quality analysis before custody transfer.
What gets measured
Water content, the most critical parameter for corrosion and hydrates.
Oxygen, which speeds corrosion and limits some storage and use options.
H2S, total sulphur, SOx and NOx, which with water can form strong acids.
Non-condensable gases such as nitrogen, argon, hydrogen, methane and carbon monoxide, which change the phase behaviour and raise the pressure needed to keep CO2 in dense phase.
Amine, glycol and oil carryover from upstream units and compressors.
ISO 27913 covers CO2 pipeline transportation systems and ISO/TR 27921 discusses CO2 stream composition. Each project sets its own limits.
Design points
The tightest specification in the chain, as the pipeline, ship, storage site and any user of the CO2 may each set different limits.
Dehydration technology: TEG for large flows and moderate dryness, molecular sieves for very low water content.
Materials for the wet sections upstream of the dryer, usually stainless steel.
Compressor lubricant carryover, controlled by coalescing filters.
Analyser sampling: short, heated lines and suitable materials so that the sample represents the stream, particularly for moisture and reactive species.
Start-up and upsets, when off-specification gas must be vented or recycled rather than sent on.
Common problems
Water slip after a dryer upset or a regeneration fault.
Glycol carryover from TEG units into downstream equipment.
Oxygen above specification from air ingress or from the capture process itself.
Slow or wrong analyser readings from poor sample systems, especially for moisture.
Hydrates and ice during depressurisation, when CO2 cools sharply.
Where Tech Inc. equipment fits
Tech Inc. supplies the CO2 dehydration unit (molecular sieve), the CO2 quality analyser system for CCUS, sampling cabinets for H2S and moisture analysers, gas sampling panels, high-pressure oil-removal coalescer skids for compressor discharge and pleated amine filter cartridges for the capture unit.
Related reading
This note is general guidance. CO2 specifications are set by each project's transport and storage operators.