top of page

Process Note: Molecular Sieve Dehydration When TEG Is Not Dry Enough

Writer: Tech Inc
Tech Inc
10 hours ago
2 min read

At a glance. Glycol dehydration is enough for most pipelines, but NGL recovery, LNG trains and some CO2 pipelines need gas so dry that any remaining water would freeze or corrode. Molecular sieves, crystalline aluminosilicates with uniform pores, adsorb water to very low levels. Plants across the world run them in pairs or trios: one bed dries while another is regenerated.

How the process works

  1. Inlet filtration. A coalescer removes liquids that would damage the sieve. Liquid water or glycol carried onto a bed breaks down the sieve and shortens its life.

  2. Adsorption. Wet gas flows down through a bed of sieve beads. Water is adsorbed in a mass-transfer zone that moves slowly down the bed during the cycle.

  3. Switching. Before the mass-transfer zone reaches the bottom, valves switch the gas to a fresh bed.

  4. Heating. A slip stream of dry gas is heated and passed upwards through the saturated bed to drive the water off.

  5. Cooling. Unheated gas cools the bed back to adsorption temperature.

  6. Regeneration gas handling. The wet regeneration gas is cooled, its water is separated, and the gas is recompressed or sent to fuel.

Choosing the sieve

  • Type 3A has the smallest pores and adsorbs water while excluding most other molecules, which limits co-adsorption and coking.

  • Type 4A is the general-purpose choice for natural gas drying.

  • Type 13X has larger pores and also removes mercaptans and some heavier compounds.

  • Acid-resistant grades are used where CO2 or H2S would attack standard sieves, which matters for CO2 dehydration in carbon capture projects.

Design points

  • Cycle time sets the bed size: longer cycles need bigger beds but fewer valve operations.

  • Superficial velocity and pressure drop must stay within limits to avoid bead movement and attrition.

  • Regeneration temperature and gas rate decide how completely each bed is restored.

  • Switching valves must seal tightly every cycle; a leaking valve sends wet gas downstream.

  • Bed support and hold-down with ceramic balls protect the sieve from flow surges.

Common problems

  • Liquid carry-over onto the bed, which causes bead breakage and dust.

  • Premature breakthrough from ageing sieve, poor regeneration or channelling.

  • Hydrothermal damage when beds are heated too fast with wet gas.

  • Dust downstream, which plugs exchangers and cold boxes unless a dust filter follows the beds.

Where Tech Inc. equipment fits

Tech Inc. builds gas dehydration skids (TEG and molecular sieve), CO2 dehydration units, inlet filter separator and coalescer skids and moisture analyser sampling cabinets that confirm the outlet dew point. Every skid is engineered to the client's gas analysis and dew point target and factory-tested before shipment.

Related reading

This note is general guidance. Each unit is designed to the project's process data and the applicable codes and standards.