Most CIP mistakes are arithmetic: percent by weight confused with percent by volume, hypochlorite strength assumed from the label, or a tank topped up after dosing. This calculator removes the first two.

How it works

Active chemical needed = target (g/L) × tank volume. Stock mass = active ÷ stock strength; stock volume = stock mass ÷ stock density. Hypochlorite is handled as available chlorine. Typical stock strengths are preloaded; overwrite them with the figures on your drum or certificate.

Worked example

500 L of 0.5% w/v caustic from 50% sodium hydroxide (1.525 g/mL): 2.5 kg active, 5 kg of stock, 3.3 L.

Limits

Respect the membrane maker's pH, temperature and free-chlorine limits, and never mix acid and hypochlorite. Add chemical to water. For protocols and the test rig that trials them, see UF backwash, CEB and CIP cleaning and the CEB testing system. All Tech Inc. calculators and converters.

Write to mail@techincresearch.com or call +1 (289) 622-1032.

Disclaimer: this calculator and article give estimates from simplified, published equations and the values you enter, for general information only and without warranty. They are not engineering, design, safety or regulatory advice and are no substitute for measurement, the equipment or chemical maker's instructions, the applicable standards or the judgement of a qualified engineer. Do not rely on them for safety-critical decisions. Tech Inc. accepts no liability for loss, damage or injury arising from their use. Equipment specifications are typical and may change; results depend on the membranes and conditions, how the equipment is used and operation in line with the operation manual. See our product information disclaimer and terms of use.