top of page

Process Note: Backwash, CEB and CIP in Ultrafiltration Systems

Writer: Tech Inc
Tech Inc
8 hours ago
2 min read

At a glance. Hollow fibre ultrafiltration (UF) removes suspended solids, bacteria and most viruses from water. It is widely used for drinking water and as pretreatment for reverse osmosis. The fibres foul as they filter, so the plant alternates between filtering and cleaning. A hydraulic backwash removes loose deposits every few tens of minutes, a chemically enhanced backwash (CEB) removes what backwash cannot, and clean-in-place (CIP) restores the membranes when everything else falls short. Water treatment plants across the world tune these cycles to their own feed water.

The cleaning hierarchy

  1. Filtration, typically 20 to 60 minutes per cycle, while the transmembrane pressure (TMP) rises slowly.

  2. Backwash: filtrate is pushed back through the fibres for a short time, often with air scour, lifting the cake off the membrane surface.

  3. Chemically enhanced backwash (CEB): a backwash with chlorine or caustic for organics and biofilm, or acid for scale and metals, followed by a soak and a rinse. Typically daily to weekly.

  4. Clean-in-place (CIP): a longer, recirculated clean with warmer or stronger chemicals, when TMP does not recover after CEB. Typically monthly to quarterly.

  5. Integrity testing: pressure decay tests confirm that no fibres are broken, as a broken fibre lets particles and pathogens through.

What to monitor

  • TMP and permeability, the flux divided by TMP and corrected for temperature.

  • Permeability recovery after each backwash, CEB and CIP, the best sign of whether cleaning is working.

  • Filtrate turbidity and SDI.

  • Pressure decay rate in integrity tests.

  • Chemical use and backwash water use, which set operating cost and recovery.

Design points

  • Flux: a conservative flux slows fouling and stretches cleaning intervals.

  • Cycle times and backwash flow, tuned on site.

  • CEB chemicals and strengths, compatible with the membrane polymer, as PVDF and PES tolerate chlorine differently.

  • Coagulant dosing ahead of UF for difficult water.

  • Neutralisation and disposal of cleaning wastes.

  • Pilot testing on the real feed water before full-scale design.

Common problems

  • Irreversible fouling that builds slowly when CEB frequency or chemistry is wrong.

  • Fibre breakage from air scour, pressure shocks or chemical attack.

  • Too much chlorine, which shortens membrane life.

  • Low recovery from backwashing too often.

  • Seasonal changes in feed water that the original settings do not cover.

Where Tech Inc. equipment fits

Tech Inc. supplies the equipment used to develop and verify cleaning regimes: the backwash and chemically enhanced backwash (CEB) testing system, the clean in place (CIP) testing system, the hollow fibre module integrity tester, the filter and membrane integrity tester, ultrafiltration pilot plants and lab hollow fibre UF modules. Full-scale ultrafiltration systems are supplied by our sister company, Davey Products.

Related reading

This note is general guidance. Cleaning chemicals, strengths and intervals follow the membrane maker's guidelines and pilot results.

Comments