Chemical Injection Dosing Calculator: ppm Dose to Pump Rate, Pump Setting and Tank Autonomy

The dose is specified in ppm; the pump is set in litres per hour. This calculator bridges the two, including the active content of the chemical as supplied and the autonomy of the day tank.
How it works
Process mass flow = volume flow × density.
Active chemical = mass flow × ppm × 10⁻⁶; neat chemical = active ÷ active fraction; volume = mass ÷ chemical density.
Pump setting = required rate ÷ pump capacity; the calculator warns outside the 10 to 90% band where diaphragm and plunger pumps are repeatable.
Worked example
5,000 bbl/d of crude at 850 kg/m³ dosed at 20 ppm with a 100% active inhibitor of 1,050 kg/m³: 28 t/h of oil, 563 g/h of chemical, 0.54 L/h, 12.9 L/day (3.4 US gal/day). A 5 L/h pump runs at 11%, and a 1,000 L day tank lasts 78 days.
Limits
Water-soluble chemicals dosed into wet streams are often specified per barrel of water, so enter the water flow alone. Doses change with temperature, water chemistry and shear; the figure here is the starting point for a residual-monitoring programme, not the end of it. Our chemical injection skids, multipoint chemical injection skids, portable chemical injection units and solar-powered injection skids are sized from exactly this calculation; the guide how to specify a chemical injection skid goes through the rest. All Tech Inc. calculators and converters.
Related tools: Liquid flow units, CIP chemical dilution, Tubing pressure drop, Water hardness units. All 57 calculators and converters.
Write to mail@techincresearch.com or call +1 (289) 622-1032.
Disclaimer: this calculator and article give estimates from simplified, published equations and the values you enter, for general information only and without warranty. They are not engineering, design, safety or regulatory advice and are no substitute for measurement, the equipment or chemical maker's instructions, the applicable standards or the judgement of a qualified engineer. Do not rely on them for safety-critical decisions. Tech Inc. accepts no liability for loss, damage or injury arising from their use. Equipment specifications are typical and may change; results depend on the fluids and conditions, how the equipment is used and operation in line with the operation manual. See our product information disclaimer and terms of use.
Sources
API, API Recommended Practice 14E / 17 TR series and injection practice overview via Petrowiki: Chemical injection (SPE PetroWiki, corrosion inhibitor dosing).
Engineering ToolBox, Parts per million (ppm) and concentration conversions.