Carman–Kozeny Calculator: Permeability and Pressure Drop of Packed Beds, Filter Cakes and Sintered Media

The Carman–Kozeny equation links what a bed is made of to how it flows: porosity and particle size on one side, permeability and pressure drop on the other. It is the working equation for filter cakes, sand beds, sintered elements, catalyst beds and depth filters.
How it works
Permeability k = φ² d² ε³ ÷ [180 (1 − ε)²], with sphericity φ, Sauter mean diameter d and porosity ε.
Pressure gradient ΔP/L = μ u ÷ k in laminar flow (particle Reynolds number below about 1).
The Ergun equation, which adds the inertial term, is shown alongside and takes over as Reynolds number rises.
Specific surface S = 6 ÷ (φ d) links the particle size to a BET or permeametry measurement.
Worked example
A 50 mm bed of 200 µm sand (sphericity 0.85, porosity 0.40) with water at 10 m/h: permeability 2.9 × 10⁻¹¹ m² (29 darcy), a pressure drop of 0.049 bar, particle Reynolds number 0.8, so the laminar form holds. Doubling the velocity doubles the drop; halving the particle size quadruples it.
Limits
The constant 180 is for random packings of roughly uniform particles between about 0.26 and 0.75 porosity; fibrous media, very wide size distributions and compressible cakes deviate. For a filter cake, porosity at the operating pressure is the number that matters, and it is measured on a test rig rather than assumed. Our filter flow and pressure drop test bench, filter integrity testing service and permeameters measure what the equation predicts; the core permeability calculator and permeability unit converter are the companions. All Tech Inc. calculators and converters.
Related tools: Core permeability and porosity, Permeability units, Vmax filter sizing, Settling velocity. All 63 calculators and converters.
Write to mail@techincresearch.com or call +1 (289) 622-1032.
Disclaimer: this calculator and article give estimates from simplified, published equations and the values you enter, for general information only and without warranty. They are not engineering, design, safety or regulatory advice and are no substitute for measurement, the equipment or chemical maker's instructions, the applicable standards or the judgement of a qualified engineer. Do not rely on them for safety-critical decisions. Tech Inc. accepts no liability for loss, damage or injury arising from their use. Equipment specifications are typical and may change; results depend on the fluids and conditions, how the equipment is used and operation in line with the operation manual. See our product information disclaimer and terms of use.
Sources
Wikipedia, Kozeny–Carman equation.
Wikipedia, Ergun equation.