Clarifiers, thickeners, settling tests and oil-water separators all start from one number: how fast a particle (or droplet) falls or rises in the liquid. This calculator gives it for a single particle across all flow regimes and corrects it for the concentration of the suspension.

How it works

  • Terminal velocity from the force balance with a drag coefficient that depends on the particle Reynolds number: Stokes (24/Re) below 0.1, Schiller–Naumann to Re 1,000, and the constant 0.44 of the Newton regime beyond; solved by iteration.

  • Hindered settling by Richardson–Zaki: u = u_t ε^n, where ε is the liquid volume fraction and n falls from 4.65 at low Reynolds number to 2.4 at high.

  • The hindered velocity sets the maximum overflow rate (surface loading) of a clarifier; the settling time over a given depth follows.

Worked example

A 100 µm quartz particle (2,650 kg/m³) in water settles at 8.0 mm/s (29 m/h), Reynolds number 0.8; in a 10 vol% suspension the hindered velocity is 5.0 mm/s (18 m/h), so a clarifier should be loaded below 18 m³/m²·h and 2 m of settling takes about 7 minutes.

Limits

Spheres are assumed; sand, flocs and oil droplets with surfactant each behave differently, and above about 30 vol% solids the bed enters compression settling. Oil droplets rising in water use the same equations with the density difference reversed. Our deoiling hydrocyclone skids, leach filtration trains and the separation and produced water range are sized from these velocities; the leach pulp density calculator gives the solids fractions that feed the hindered-settling term. All Tech Inc. calculators and converters.

Write to mail@techincresearch.com or call +1 (289) 622-1032.

Disclaimer: this calculator and article give estimates from simplified, published equations and the values you enter, for general information only and without warranty. They are not engineering, design, safety or regulatory advice and are no substitute for measurement, the equipment or chemical maker's instructions, the applicable standards or the judgement of a qualified engineer. Do not rely on them for safety-critical decisions. Tech Inc. accepts no liability for loss, damage or injury arising from their use. Equipment specifications are typical and may change; results depend on the fluids and conditions, how the equipment is used and operation in line with the operation manual. See our product information disclaimer and terms of use.