Adsorbent Breakthrough Capacity Calculator: Dynamic Capacity, Bed Utilisation and Mass-Transfer Zone

Writer: Tech Inc
Tech Inc
1 day ago
2 min read

A breakthrough curve is the real test of a sorbent: isotherms say what it can hold, the curve says what it holds before the outlet drifts. This calculator converts the curve into the capacities a process engineer needs.

How it works

  • Molar feed rate of the adsorbate from standard gas flow and inlet concentration.

  • Dynamic capacity = feed rate × breakthrough time ÷ sorbent mass.

  • Saturation capacity adds the mass adsorbed between breakthrough and exhaustion, using the mean outlet fraction you enter (0.5 for a symmetric S-curve; integrate for anything else).

  • Bed utilisation = t_b ÷ t_e; mass-transfer-zone length = L × (1 − t_b ÷ t_e).

Worked example

200 NmL/min of 15% CO₂ over 10 g in a 100 mm bed, breakthrough at 15 minutes and exhaustion at 22: 2.0 mmol/g (88 mg/g, 8.8 wt%) dynamic, 2.5 mmol/g saturation, 68% utilisation and a 32 mm mass-transfer zone, a third of the bed.

Limits

Subtract the rig's dead-volume response (run a blank with an inert bed) before reading the times, and hold feed pressure and temperature constant: heat of adsorption raises bed temperature and lowers capacity. Humidity changes everything for zeolites and amine sorbents, so report it. Our solid sorbent CO₂ breakthrough test rig, multicomponent breakthrough analyser, PSA/VPSA adsorption test unit and high-pressure gas adsorption isotherm analyser generate these curves; the carbon capture pilot rig guide puts them in context. All Tech Inc. calculators and converters.

Write to mail@techincresearch.com or call +1 (289) 622-1032.

Disclaimer: this calculator and article give estimates from simplified, published equations and the values you enter, for general information only and without warranty. They are not engineering, design, safety or regulatory advice and are no substitute for measurement, the equipment or chemical maker's instructions, the applicable standards or the judgement of a qualified engineer. Do not rely on them for safety-critical decisions. Tech Inc. accepts no liability for loss, damage or injury arising from their use. Equipment specifications are typical and may change; results depend on the fluids and conditions, how the equipment is used and operation in line with the operation manual. See our product information disclaimer and terms of use.