top of page

CO₂ Capture Rate Calculator: Capture Efficiency, Tonnes Captured, Amine Circulation and Reboiler Duty

Writer: Tech Inc
Tech Inc
1 day ago
2 min read

Capture rate is the headline number of a carbon capture pilot, and it is easy to get wrong by comparing inlet and outlet percentages directly. This calculator does the balance on the inert gas, then sizes the solvent loop that delivers it.

How it works

  • Dry gas flow from the wet flow and water content; CO₂ in = dry flow × y_in; inert flow = dry flow × (1 − y_in); CO₂ out = inert × y_out ÷ (1 − y_out).

  • Capture rate = (CO₂ in − CO₂ out) ÷ CO₂ in. Captured mass at 44.01 kg/kmol, per hour, day and 330-day year.

  • Solvent circulation = CO₂ captured ÷ [(rich − lean loading) × amine molarity]; L/G from the solvent density.

  • Reboiler duty = captured rate × specific reboiler duty.

Worked example

1,000 Nm³/h of wet flue gas with 8% water at 12% CO₂ in and 1.3% out (dry): 90.3% capture, 196 kg/h, 4.7 t/day, 1,550 t/year. With 30% MEA (4.9 kmol/m³) cycling between 0.22 and 0.48 loading the circulation is 3.5 m³/h, L/G 2.8 kg/kg, and at 3.8 GJ/t the reboiler needs 0.21 MW.

Limits

Loadings must be measured (titration or TIC analysis) on the rich and lean streams, not assumed; degradation products and heat-stable salts lower the working capacity. Specific reboiler duty depends on stripper pressure, lean loading and heat integration; 3.6 to 4.0 GJ/t is first-generation MEA, advanced solvents reach 2.5 to 3. Our CO₂ capture solvent screening systems, carbon capture pilot rigs and CO₂ quality analyser systems measure the inputs to this calculation; the carbon capture pilot rig guide explains the test campaign. All Tech Inc. calculators and converters.

Write to mail@techincresearch.com or call +1 (289) 622-1032.

Disclaimer: this calculator and article give estimates from simplified, published equations and the values you enter, for general information only and without warranty. They are not engineering, design, safety or regulatory advice and are no substitute for measurement, the equipment or chemical maker's instructions, the applicable standards or the judgement of a qualified engineer. Do not rely on them for safety-critical decisions. Tech Inc. accepts no liability for loss, damage or injury arising from their use. Equipment specifications are typical and may change; results depend on the fluids and conditions, how the equipment is used and operation in line with the operation manual. See our product information disclaimer and terms of use.

Sources

Comments