Membrane Module Area Calculator: Hollow Fibre and Spiral Wound

Flux is permeate per area, so the area of a hand-made module must be right. This calculator gives it for hollow-fibre bundles and spiral-wound leaves, with packing density and velocities.
How it works
Hollow fibre: outer area = n × π × OD × L; inner area = n × π × ID × L. Report which one you divided by. Packing density = n × OD² ÷ housing ID².
Spiral wound: active area = 2 × leaves × length × width × (1 − glue-line loss).
Worked example
1,000 fibres, 1.3/0.7 mm, 500 mm long in an 80 mm housing: 2.04 m² outside, 1.10 m² inside, 26% packing density. Four 900 × 950 mm leaves with 12% glue loss: 6.0 m².
Limits
Effective length excludes the potted ends. Packing densities above about 60% starve the shell side; see hollow fibre vs flat sheet. Our potting centrifuge, module housing kits and spiral winding machine make the modules this tool describes. All Tech Inc. calculators and converters.
Related tools: Cross-flow velocity, Membrane flux and permeability, TFF and diafiltration, Vmax filter sizing. All 57 calculators and converters.
Write to mail@techincresearch.com or call +1 (289) 622-1032.
Disclaimer: this calculator and article give estimates from simplified, published equations and the values you enter, for general information only and without warranty. They are not engineering, design, safety or regulatory advice and are no substitute for measurement, the equipment or chemical maker's instructions, the applicable standards or the judgement of a qualified engineer. Do not rely on them for safety-critical decisions. Tech Inc. accepts no liability for loss, damage or injury arising from their use. Equipment specifications are typical and may change; results depend on the membranes and conditions, how the equipment is used and operation in line with the operation manual. See our product information disclaimer and terms of use.
Sources
Angewandte Chemie International Edition (2018), Belfort, Membrane Filtration with Liquids, via OSTI.