Vessel Lining and Coating Compatibility Chart: Rubber, PTFE, PFA, PVDF, Glass, Epoxy, Vinyl Ester and Acid Brick Against 42 Fluids

A lined carbon-steel vessel is usually the cheapest way to hold an aggressive fluid, and the lining is the part that fails. This chart ranks seventeen lining and coating systems, from soft natural rubber and ebonite through butyl, EPDM and chloroprene, the fluoropolymers (PTFE, PFA, PVDF), polyolefins, glass-lined steel, epoxy, vinyl ester, phenolic and polyurethane coatings to acid brick and cement mortar, against the same 42 fluids and conditions as our metal and seal charts. Each lining carries its form, thickness and temperature limit, so the chart answers the second question as well: sheet lining, spray coating or brick?
How to read it
Family, not product. "Epoxy" spans a general-purpose amine-cured tank coating and a glass-flake novolac rated for hot crude; the rating is for the family at moderate temperature, and the applicator's immersion data on the real fluid is the final word.
Linings fail mechanically more often than chemically. Disbonding at nozzles, blistering under hot water or cathodic protection, cracking of ebonite and glass on impact or thermal shock, and decompression blistering in gas service are the usual causes; the chart flags temperature and decompression separately.
Permeation is the fluoropolymer problem. PTFE and PFA resist nearly everything, but hot HCl, chlorine and water pass through them slowly and corrode the steel behind; a vented or bonded lining and a permeation calculation are part of the design.
Thickness and form decide the duty. Sheet rubber at 3 to 6 mm takes abrasion and impact; a 300 µm coating does not. Acid brick takes heat and abrasion and depends entirely on the membrane behind it.
Handover tests are the same for every system: holiday (spark) testing to the applicator's voltage, adhesion testing and dry film thickness, with the records kept with the vessel.
The choices that come up most
Hydrochloric acid storage: soft natural rubber or a soft/hard/soft rubber sandwich at ambient; PP or PE tanks for dilute acid; PFA or PVDF when the acid is hot or high-purity.
Sulphuric acid: rubber, PP and vinyl ester in the dilute range; acid brick on a membrane, glass or PTFE for hot concentrated acid; above about 93 % carbon steel is often used unlined.
Caustic: rubber, PP, PE and epoxy; EPDM and butyl when hot; glass-lined steel and PVDF are limited and phenolic fails.
Hypochlorite and chlorine scrubbers: PVDF, vinyl ester glass-flake and EPDM; PP at ambient only.
Crude, fuels and produced water: epoxy (novolac for hot or sour service) and phenolic baked coatings; polyurethane for water and effluent tanks.
Solvents and pharmaceutical reactors: glass-lined steel, with PFA- or PTFE-lined vessels where fluorides or hot caustic rule glass out.
Seawater and brine: rubber, epoxy or cement mortar; the economics, not the chemistry, decide.
Our equipment
PTFE-lined acid digestion vessels and hydrothermal autoclaves, battery acid dilution and cooling skids, chemical cleaning, pickling and passivation skids, duplex chemical injection day tanks, high-salt buffer hold tanks, caustic fusion reactors, compressor suction scrubber skids, special-alloy process vessels and peel and adhesion testers for lining qualification. Related guides: API 650 and API 653 storage tanks, ASME Section VIII pressure vessels, ISO 21457 materials selection, ASTM A380 cleaning, pickling and passivation. All Tech Inc. calculators and converters.
Write to mail@techincresearch.com or call +1 (289) 622-1032.
Disclaimer: this calculator and article give estimates from simplified, published equations and the values you enter, for general information only and without warranty. They are not engineering, design, safety or regulatory advice and are no substitute for measurement, the equipment or chemical maker's instructions, the applicable standards or the judgement of a qualified engineer. Do not rely on them for safety-critical decisions. Tech Inc. accepts no liability for loss, damage or injury arising from their use. Equipment specifications are typical and may change; results depend on the fluids and conditions, how the equipment is used and operation in line with the operation manual. See our product information disclaimer and terms of use.
Sources
ASTM International, ASTM D5162 Standard Practice for Discontinuity (Holiday) Testing of Nonconductive Protective Coating on Metallic Substrates, standard summary page.
ASTM International, ASTM D4541 Standard Test Method for Pull-Off Strength of Coatings Using Portable Adhesion Testers, standard summary page.
AMPP (formerly NACE International and SSPC), ampp.org, publisher of the tank-lining and coating standards behind generic lining guidance.