Vapour Pressure Calculator (Antoine Equation): Water and 20 Solvents, with Boiling Point at Any Pressure

Vapour pressure decides the driving force in membrane distillation, the flux in pervaporation, the flash risk in a sample line, the NPSH of a hot pump and the operating pressure of a vacuum still. This calculator gives it for water and twenty common solvents from the Antoine equation, with the coefficients in view.
How it works
log₁₀ P(mmHg) = A − B ÷ (C + T°C), the three-constant Antoine form, with coefficients from the widely tabulated Lange/Yaws set for each liquid and the fit range shown.
Converts the result to bar, kPa, mmHg and psia; reports the slope dP/dT, which is the sensitivity that matters for membrane distillation and for temperature control.
Inverts the equation for the boiling point at the pressure you enter (a vacuum setting, an altitude or a reactor pressure) and the normal boiling point at 760 mmHg.
A custom option takes your own A, B and C for a liquid not on the list.
Worked example
Water at 60 °C: 0.199 bar(a) (149 mmHg), slope 9.2 mbar/K; boiling point at 1,013 mbar, 100 °C. Switching to methanol at the same temperature gives about 0.84 bar(a), which is why a methanol-water separation by pervaporation or distillation is so much easier than, say, ethanol-water at the azeotrope.
Limits
Antoine coefficients are valid only over their fit range, typically from near the freezing point to a little above the normal boiling point; the calculator flags extrapolation. Mixtures need activity coefficients (Raoult's law with corrections) and are not covered; for process design use NIST or DIPPR data. Our membrane distillation test skids, pervaporation testing systems and solvent recovery systems run on these numbers; the membrane distillation flux calculator and pervaporation calculator use the same vapour pressures, and the pump NPSH calculator needs them for hot liquids. All Tech Inc. calculators and converters.
Related tools: Membrane distillation flux, Pervaporation, Pump NPSH available, RVP to TVP. All 67 calculators and converters.
Write to mail@techincresearch.com or call +1 (289) 622-1032.
Disclaimer: this calculator and article give estimates from simplified, published equations and the values you enter, for general information only and without warranty. They are not engineering, design, safety or regulatory advice and are no substitute for measurement, the equipment or chemical maker's instructions, the applicable standards or the judgement of a qualified engineer. Do not rely on them for safety-critical decisions. Tech Inc. accepts no liability for loss, damage or injury arising from their use. Equipment specifications are typical and may change; results depend on the fluids and conditions, how the equipment is used and operation in line with the operation manual. See our product information disclaimer and terms of use.