top of page

Gas Conditioning Skids Compared: Flow, Pressure, Dew Point and Filtration

Writer: Tech Inc
Tech Inc
6 hours ago
5 min read
Gas Conditioning Skids Compared: Flow, Pressure, Dew Point and Filtration

Bottom line: for turbine and engine fuel, the fuel gas conditioning skid delivers gas superheated typically 28 °C (50 °F) above its hydrocarbon dew point. Wet gas needs the dehydration skid: TEG for water dew points typically down to −10 °C (14 °F), molecular sieve down to −70 °C (−94 °F). Pressure reduction and metering need the pressure reducing and metering station, and liquids and solids the filter separator. Biogas, CO2 and vent-gas recovery units are in the second table.


The tables list each product with the figures published on its product page. Where a page gives no figure, the cell shows a dash: ask us and we will confirm it for your duty.


Gas treatment and supply skids

Product

Models

Flow or size

Pressure

Performance

Build and code

TI-FGC-2 to TI-FGC-50

about 2,000 to 50,000 Sm³/h

outlet regulated to the consumer's supply pressure

superheat typically 28 °C (50 °F) above hydrocarbon dew point; filtration typically to 0.3 µm

electric or shell-and-tube heater; ASME VIII vessels

TI-FSC-H, V, D and L; about DN 150 to 1,200

sized to the duty

typically Class 150 to 2500

solids and liquids typically down to 0.3 µm

ASME VIII; quick-opening closure; automatic drain

TI-GDS-1 to TI-GDS-25

about 1 to 25 MMSCFD

–

water dew point typically down to −10 °C (14 °F) with TEG, −70 °C (−94 °F) with molecular sieve

TEG reboiler and still, or molecular-sieve towers; PLC sequencing

TI-PRMS-500 to TI-PRMS-200000

about 500 to 200,000 Sm³/h

inlet up to Class 600

turbine, ultrasonic or rotary meter with flow computer

ASME B31.3 / B31.8; single, 1+1 or 2+1 streams

TI-CDS-100 to TI-CDS-3000

about 100 to 3,000 Sm³/h

inlet up to 250 bar (3,630 psi)(g); outlet typically 0.1 to 10 bar (1 to 145 psi)(g)

heating offsets the cooling from the pressure drop; slam-shut and relief valves

water bath, hot-water or electric heating; skid, trailer or container

TI-LPV-50 to TI-LPV-600

about 50 to 600 kg/h vaporising

outlet regulated to the consumer's requirement

liquid and vapour metering; relief and excess-flow valves

electric or water bath heat source

TI-IGC-10, 30, 100 and H

about 10 to 100 Sm³/h

inlet to about 100 barg (1,450 psig); outlet about 2 to 10 barg (29 to 145 psig)

liquid-free gas, filtered to about 1 µm

carbon steel or 316L; NACE MR0175 / ISO 15156 for sour gas; ASME B31.3 and VIII

TI-EFH-50 to TI-EFH-1000

about 50 kW to 1 MW duty

to ASME Class 600

outlet to about 200 °C (392 °F), controlled

ASME VIII; Ex panel for Zone 1 or 2

–

typically about 800 Nm³/h

typically 70–100 barg (1,020–1,450 psig)

heating, liquid knock-out, coalescing and particle filtration

API 692; ASME VIII; duplex filter housings

TI-CSS-300 to TI-CSS-1200; DN 300 to 1,200

sized to the gas flow and liquid load

to client specification

wire mesh or vane pack mist eliminator

ASME VIII; carbon steel, low-temperature carbon steel or stainless

TI-ORC-25, 45 and 60

–

to about 25, 45 or 60 MPa

coalescer grades selected to the required outlet oil content

ASME VIII; carbon steel or SS316

TI-BPF-1 to TI-BPF-30

about 1 to 30 MMSm³/d

ASME Class 600 or 900

cyclones for coarse solids; cartridges to about 1 to 3 µm

ASME VIII Div. 1, B31.3 or B31.8; NACE MR0175 / ISO 15156


Recovery, biogas, CO2 and research units

Product

Models

Flow or size

Pressure

Performance

Build and code

–

typically 0.1–0.5 MMSCFD

discharge to suit the receiving system

screw compressor with variable-speed control

PLC control; carbon or stainless steel

TI-FGRU-LR1 (2 × 100%) or TI-FGRU-LR3 (3 × 50%)

sized to the flare header base load

discharge to client specification

liquid-ring compressors to API 681

ASME VIII; materials for sour service where needed

TI-BHS-100 to TI-BHS-1000

about 100 to 1,000 Nm³/h

–

outlet H2S to the limit of the upgrading unit or engine

lead/lag twin vessels; coated carbon steel or stainless

TI-BUG-250, 500 and 1000

about 250 to 1,000 Nm³/h raw biogas

discharge up to 250 bar (3,630 psi)

vehicle-grade methane from three-stage hollow-fibre membranes

skid or container; PLC and SCADA with online analyser

–

typically 150–600 t of CO2 a day

to suit the compression stage or tie-in

outlet water down to ppm level

two molecular-sieve towers; stainless; ASME VIII

TI-FCR-50 to TI-FCR-600

about 50 to 600 kg/h of CO2

–

liquid CO2 to the purity the plant specifies

SS304 or SS316; ASME VIII

TI-AFP-1 to TI-AFP-40

about 1 to 40 m³/h slipstream

–

prefilter about 5 to 25 µm; activated carbon bed; after-filter about 5 to 10 µm

carbon steel, 316L or duplex; ASME VIII Div. 1

TI-CCP-1 to TI-CCP-100

about 1 to 100 kg CO2 per day

atmospheric absorber; stripper to about 3 barg (44 psig)

measures CO2 in and out, solvent loading and reboiler duty

316L or duplex; ASME VIII Div. 1 and B31.3

TI-GFR-5 to TI-GFR-500

about 5 to 500 L working volume

to about 10 barg (145 psig)

to about 80 °C (176 °F); steam sterilisation at about 121 °C (250 °F)

polished 316L; ASME VIII Div. 1 or PED


How to choose

  • Start from the gas analysis: composition, water content, H2S and liquids drive every other choice.

  • Fix the outlet specification first: dew point, particle size, pressure and temperature at the consumer.

  • Allow for the pressure drop: a large drop cools the gas, so check whether heating is needed to stay above the hydrocarbon and water dew points.

  • Sour gas needs materials and seals to NACE MR0175 / ISO 15156.

  • Decide on spares: duty and standby trains let you change elements without shutting down.



Before you order

Send us your samples, operating conditions and the standard you work to, and we will confirm the model. Equipment carries our standard warranty and installation, training and service terms: see Service and Support and our Terms of Sale. Send an enquiry or email mail@techincresearch.com.


Data are typical and taken from each product page and datasheet; final design is to the client specification and the order acknowledgement. Check the product page or ask us before you order.

Comments


bottom of page