The Tech Inc. Electric Fuel-Gas and Process Heater Package heats fuel gas and process streams with electricity, where there is no steam or where a burner is not wanted. The flowing gas passes through a pressure vessel holding electric heating elements; a thyristor control panel sets the outlet temperature, and independent high-temperature cut-outs on the elements and the outlet protect the package. Fuel gas is kept above its hydrocarbon and water dew points after pressure reduction.
At a glance: about 50 kW to 1 MW · to ASME Class 600 · outlet to about 200 °C · thyristor control · Ex terminal box and panel · element and outlet cut-outs
Main components
- Pressure vessel with flanged electric heating bundle
- Thyristor (SCR) power controller in an Ex or safe-area panel
- Element and outlet temperature sensors with high-temperature cut-outs
- Inlet and outlet isolation, relief valve and drain
- Insulation and cladding
- Skid with lifting points
Applications: gas-turbine fuel-gas systems, pressure-reducing and metering stations, process gas preheating, regeneration gas heating and nitrogen heating.
Send your process data and specification to mail@techincresearch.com or call +1 (289) 622-1032 for a P&ID, GA drawing and quotation.