At a glance. Transmission pipelines run at high pressure, but city networks, power stations and factories need gas at a lower, steady pressure and need to know exactly how much they have taken. A pressure reducing and metering station (PRMS) does both, safely and without interrupting supply. Utilities and industrial users across the world rely on them at every custody transfer point.

How the process works

  1. Inlet isolation and filtration. Gas enters through an emergency shut-off valve and passes through filters or filter separators that remove dust and liquids that would damage regulators and meters.

  2. Heating. Gas cools as its pressure drops, by roughly half a degree Celsius for every bar of reduction. Where the drop is large, a water-bath or electric heater warms the gas first so that the outlet does not freeze, form hydrates or fall below the dew point.

  3. Pressure reduction. Regulator streams reduce the pressure. Each stream normally has an active regulator and a monitor regulator, which takes over if the active one fails open, plus a slam-shut valve that closes on over- or under-pressure.

  4. Redundancy. Two or more parallel streams let one be serviced while the other carries the load.

  5. Metering. Ultrasonic, turbine or rotary meters measure the flow; a flow computer corrects it to standard conditions, often using a gas chromatograph for energy content.

  6. Odorisation. For distribution networks, an odorisation skid adds odorant so leaks can be smelt.

  7. Relief and venting. Token relief valves protect against small leaks past closed regulators.

Design points

  • Inlet and outlet pressure ranges, now and in the future.

  • Maximum and minimum flows, which set regulator and meter sizing and turndown.

  • Noise and velocity limits in pipework downstream of the regulators.

  • Heater duty for the worst case of high flow, high pressure drop and cold gas.

  • Metering accuracy class and the need for custody transfer approval.

  • Remote monitoring of pressures, flows, filter differential pressure and alarms.

Common problems

  • Regulator instability from oversizing or poor sensing line location.

  • Freezing at regulators where heating was undersized.

  • Dirty gas that damages regulator seats and meter internals.

  • Spurious slam-shut trips from settings that are too close to normal operating pressure.

Where Tech Inc. equipment fits

Tech Inc. builds pressure reducing and metering stations, hydrogen and industrial gas pressure reducing stations, gas metering skids, gas odorisation skids and CNG decompression skids. Each station is engineered to the client's pressures, flows and standards, built in-house and factory-tested.

Related reading

This note is general guidance. Each station is designed to the project's data and the applicable codes and standards.