Seaweed Hydrogels for Clean Water: UTS Thesis Measures Pores with TECHPoro

At a glance. Kappa carrageenan comes from red seaweed and goes into ice cream. In a 2026 thesis at the University of Technology Sydney, Lilyan Alsaka turned it into hydrogels that treat landfill leachate, remove the "forever chemical" PFOA and recover metal ions. Pore sizes throughout the work were measured on the TECHPoro capillary flow porometer, with samples prepared in Techporo wetting liquid.
Why this matters
Hydrogels absorb water, respond to pH, temperature and salt, and can be regenerated. Made from a cheap, renewable seaweed polysaccharide, they could take on pollutants that are expensive to treat any other way, from the dark organics in leachate to PFOA, one of the most persistent compounds in water.
What the research covers
Supervised by Dr Ali Altaee and Distinguished Professor T M Indra Mahlia, the thesis develops a family of kappa carrageenan materials:
A carrageenan and vanillin composite hydrogel for landfill leachate treatment.
Gravity-driven carrageenan hydrogels with activated carbon or vanillin for PFOA-contaminated wastewater.
A carrageenan, activated carbon and polyethyleneimine hydrogel that removes and recovers metal ions from leachate.
A carrageenan, cellulose nanofibre and graphene oxide composite membrane for water purification.
Where Tech Inc. came in
Pore size controls what a hydrogel lets through and what it holds. In the chapters on leachate, PFOA and metal recovery, pore size analysis was carried out on the TECHPoro capillary flow porometer. The hydrogel samples were soaked in Techporo wetting liquid for 24 hours before analysis so that the liquid fully filled the pores. That preparation step matters for soft, swollen materials: a partly wetted gel gives a misleading pore size distribution.
Why porometry suits gels and membranes
Capillary flow porometry measures the through-pores that actually carry flow, and it does so without the high pressures of mercury intrusion that can crush soft samples. It is quick, needs only a small disc and works on hydrogels, membranes, nanofibre mats and filter media alike. See how it compares with mercury porosimetry.
What it means for your lab
If you work with gels, aerogels or soft membranes, our porometers and wetting liquids are set up for them, and our testing service can measure samples for you. The same UTS group's membrane distillation studies with the AL-500 are covered here and here.
The paper
Alsaka, L. Y. M. (2026). Development of gel materials for water purification. Thesis, University of Technology Sydney. hdl:10453/197252
Read the full paper at the publisher for methods, data and figures.
Part of the Research with Tech Inc. series
This post is one of a series on published research made with Tech Inc. equipment and materials. See the full list on Research using Tech Inc. equipment. Next in the series: 3,500 Hours of Membrane Distillation on Tech Inc. Capillary PTFE Membranes at ZUT Szczecin.
Published with our equipment? Send the reference to mail@techincresearch.com and we will feature your work. To discuss equipment for a similar study, call +1 (289) 622-1032 or write to mail@techincresearch.com.