Anna University and CSIR-CLRI Pair Electro-Oxidation With an MBR on Tannery Effluent

At a glance. Researchers at Anna University and CSIR-Central Leather Research Institute in Chennai treated real tannery effluent in a 57-litre pilot membrane bioreactor, with and without electro-oxidation pretreatment. The microfiltration membrane came from Davey in Chennai, Tech Inc.'s sister company in the Davey Group. With electro-oxidation, COD fell from 4,800 to 192 mg/L and the membrane kept its flux better.
Why this matters
Tannery effluent is one of the hardest industrial wastewaters to treat: high in organics, nitrogen and salt. Membrane bioreactors treat it well, but soluble microbial products build a cake layer and block pores, so flux falls and membranes are replaced early. Electro-oxidation upstream breaks down part of that load before it reaches the membrane.
What the team did
Kamalakannan Vasanthapalaniappan, Kavitha Palani, Shanmuga Sundar Saravanabhavan, Narendranath Jonna, Maharaja Pounsamy, Kannan Natarajan, Yun Suk Huh and Balasubramanian Natesan ran a 57-litre acrylic pilot that combines activated sludge and microfiltration in one reactor. The electro-oxidation stage used a titanium anode coated with ruthenium and iridium oxides and a stainless steel cathode, 25 × 17 cm, 2 cm apart, at 0.15 mA/cm². The feed was effluent from a common effluent treatment plant in Chennai, with MLSS at 3,200 mg/L and a six-hour hydraulic retention time.
Where the Davey Group came in
The microfiltration membrane was procured from Davey in Chennai (the paper names the supplier as Davey Industries; the company is Davey Products, part of the Davey Group with Tech Inc.). It was a reinforced PVDF membrane with 0.22 µm pores and a filtration area of 0.5372 m² across three modules. Reinforcement matters with tannery effluent: the membrane was backwashed every hour with sodium hypochlorite dosing, and an unreinforced fibre would not stand that for long.
Results that stand out
COD fell from 4,800 mg/L to 1,800 with the MBR alone and to 192 with electro-oxidation; the paper reports 97% removal.
BOD fell from 1,100 to 300 and 27 mg/L; total nitrogen from 140.8 to 41 and 7.83 mg/L.
TOC fell from 734.9 to 152 and 59.88 mg/L.
Both systems started at 17 L/m²·h; the authors report 50% better flux with electro-oxidation, while flux in the plain MBR fell faster.
Energy use was almost unchanged: 1.3 kWh/m³ for the MBR and 1.32 kWh/m³ with electro-oxidation.
The biodegradability index rose to 0.6, against 0.3 for the MBR alone.
What it means for your lab
Fouling control is where MBR research is moving, from pretreatment to membrane chemistry. We build membrane bioreactor systems from lab to pilot scale and supply hollow fibre membranes for them. For design figures, read our guide to MBR design parameters for lab and pilot work.
The paper
Vasanthapalaniappan, K., Palani, K., Saravanabhavan, S. S., Jonna, N., Pounsamy, M., Natarajan, K., Huh, Y. S. and Natesan, B. (2021). A study on novel coupled membrane bioreactor with electro oxidation for biofouling reduction. Environmental Engineering Research 26(4), 200039. doi:10.4491/eer.2020.039
Read the full paper at the publisher for methods, data and figures.
Part of the Research with Tech Inc. series
This post is one of a series on published research made with Tech Inc. equipment and materials. See the full list on Research using Tech Inc. equipment. Next in the series: CIPET Bhubaneswar Builds a Plant-Based Absorbent Membrane on a Tech Inc. Casting Machine.
Published with our equipment? Send the reference to mail@techincresearch.com and we will feature your work. To discuss equipment for a similar study, call +1 (289) 622-1032 or write to mail@techincresearch.com.