top of page

NACE SP0169 Explained: Cathodic Protection and Control of External Corrosion on Buried and Submerged Piping

Writer: Tech Inc
Tech Inc
4 minutes ago
2 min read

NACE SP0169, Control of External Corrosion on Underground or Submerged Metallic Piping Systems (2013 edition as listed by ANSI; now published by AMPP, which succeeded NACE) is the standard practice behind cathodic protection of pipelines, station piping, tank bottoms and buried utilities. ANSI's catalogue lists it as the standard that presents procedures and practices for achieving effective control of external corrosion on buried or submerged metallic piping systems.

What it covers

Corrosion-control design for new systems (coatings, cathodic protection, electrical isolation and casings), the criteria that indicate adequate protection (the familiar −850 mV potential to a copper/copper-sulphate reference electrode with IR drop considered, the 100 mV polarisation shift and related criteria), the design of galvanic (sacrificial) and impressed-current systems, installation, interference with foreign structures, monitoring and surveys (potential surveys, close-interval surveys, coupons) and record keeping.

Our commentary

  • External and internal corrosion are different programmes. SP0169 protects the outside of the pipe; the inside, where produced water, CO2 and H2S act, is controlled by inhibitors, dehydration and monitoring with coupons and probes through access fittings. A pipeline integrity plan needs both.

  • Coating first, CP second. Cathodic protection current goes to the coating defects; a good coating makes CP cheap and effective, a bad one makes it a large power bill.

  • Reference electrodes and surveys are the measurement; a portable copper/copper-sulphate electrode and a calibrated voltmeter are the inspector's instruments, and the survey technique (IR-free, instant-off) decides whether the criterion is met.

  • Station piping and tank bottoms are often the weak points: isolation flanges, casings and the interface with above-ground piping need to be designed into the CP system, not added afterwards.

Our equipment

Send your application, materials and the standards your contract names to mail@techincresearch.com or call +1 (289) 622-1032, and we will return a configuration, datasheet and quotation.

This article is our commentary on the standard's published scope, not a substitute for the standard itself; always work to the current edition named in your contract. Equipment specifications may change; performance depends on the application, how the equipment is used and operation in line with the operation manual.