ISO 4406 and ISO 4407 Explained: Oil Cleanliness Codes, Particle Counting and What 18/16/13 Means

ISO 4406:2021, Hydraulic fluid power — Fluids — Method for coding the level of contamination by solid particles (edition 4, confirmed 2026) defines the code that appears on every hydraulic and lubricant cleanliness specification. ISO's abstract says the document specifies the code used to define the quantity of solid particles in the fluid of a hydraulic system. ISO 4407, the companion standard, covers counting particles by the microscope method on a membrane; automatic particle counters calibrated to ISO 11171 are the usual alternative.
What it covers
The code is three scale numbers, for particles larger than 4 µm(c), 6 µm(c) and 14 µm(c) per millilitre; each step in the scale doubles the count, so 18/16/13 means 1,300 to 2,500 particles above 4 µm(c), 320 to 640 above 6 µm(c) and 40 to 80 above 14 µm(c) per mL. The "(c)" marks sizes measured by a counter calibrated to ISO 11171 with the certified dust, which is why older two-number codes and newer three-number codes are not interchangeable. Our ISO 4406 cleanliness code calculator converts counts to codes and back.
Our commentary
Set the target from the most sensitive component. Servo valves and high-pressure piston pumps want cleaner oil (around 16/14/11 or better) than gear pumps and cylinders; the machine maker's table is the starting point, and a notch cleaner buys life.
A filter rating is not a cleanliness level. A β-rated element (ISO 16889) reaching a target depends on flow split, ingression and the reservoir; verify with a count, not with the filter datasheet. Our ISO 4406 and beta ratio calculator relates the two.
New oil is not clean oil. Drum oil commonly arrives several codes dirtier than a servo system allows; filter on filling, through a cart with a fine element.
Sample the same way every time. Mid-line, with the system running and warm, after flushing the valve; a bottle from the drain plug reads the sediment, not the oil.
Water is a separate code. ISO 4406 counts solids only; water (ASTM D6304) and varnish need their own tests.
Our equipment
Mobile oil filtration carts, hydraulic oil flushing units, heated high-velocity oil flushing skids, lube and control oil filter elements and lube oil filter test benches (ISO 4548). All our standards guides.
Send your application, materials and the standards your contract names to mail@techincresearch.com or call +1 (289) 622-1032, and we will return a configuration, datasheet and quotation.
This article is our commentary on the standard's published scope, not a substitute for the standard itself; always work to the current edition named in your contract. Equipment specifications may change; performance depends on the application, how the equipment is used and operation in line with the operation manual.
Sources
ISO, ISO 4406:2021 Hydraulic fluid power — Fluids — Method for coding the level of contamination by solid particles, standard page and abstract.
ISO, ISO 11171:2022 Hydraulic fluid power — Calibration of automatic particle counters for liquids, standard page and abstract.





Comments