REACH and RoHS Explained: Substance Restrictions, SVHC Declarations and What They Mean for Filters, Membranes and Equipment

Regulation (EC) No 1907/2006 (REACH) governs the registration, evaluation, authorisation and restriction of chemicals in the EU; Directive 2011/65/EU (RoHS) restricts certain hazardous substances in electrical and electronic equipment. Both are on EUR-Lex; both apply to products placed on the EU market wherever they are made.
What they cover
REACH requires manufacturers and importers to register substances above one tonne a year, restricts listed substances in Annex XVII (for example certain phthalates, PFOA-related substances, lead in some articles), and requires suppliers of articles containing a Substance of Very High Concern above 0.1 % by weight to inform recipients (the SVHC candidate list is updated twice a year). Authorisation (Annex XIV) applies to substances that may not be used without permission. RoHS restricts ten substances in electrical and electronic equipment (lead, mercury, cadmium, hexavalent chromium, two brominated flame retardants and four phthalates) above set concentrations in homogeneous materials, with exemptions listed in its annexes and categories of equipment with different dates; industrial monitoring and control instruments are a category of their own.
Our commentary: answering the questionnaire
Articles versus mixtures. A filter cartridge, a membrane or a skid is an article under REACH: the duty is to communicate SVHC content, not to register. A cleaning chemical or a membrane casting solvent is a substance or mixture with a safety data sheet and, above the tonnage, a registration by the EU importer.
Fluoropolymers are the live topic. PTFE, PVDF and PFA membranes and seals are under the EU's proposed PFAS restriction; the current position is that fluoropolymers are not restricted, but a supplier should be able to state the polymer and confirm that no restricted processing aids remain. Watch the restriction's progress before specifying.
RoHS applies to the electrical equipment, not to the pipework: an analyser, a controller or a panel needs a RoHS declaration with the exemptions used (lead in high-temperature solder, for instance); a stainless-steel vessel does not.
Keep the evidence upstream. Our declarations rest on material certificates and supplier declarations for each purchased component; a questionnaire answered without them is an opinion.
Our equipment
PTFE, PVDF, PES and nylon membrane filters, capsule filters, syringe filters and the filters and consumables range, with substance declarations on request. All our standards guides.
Send your application, materials and the standards your contract names to mail@techincresearch.com or call +1 (289) 622-1032, and we will return a configuration, datasheet and quotation.
This article is our commentary on the standard's published scope, not a substitute for the standard itself; always work to the current edition named in your contract. Equipment specifications may change; performance depends on the application, how the equipment is used and operation in line with the operation manual.
Sources
EUR-Lex, Regulation (EC) No 1907/2006 concerning the Registration, Evaluation, Authorisation and Restriction of Chemicals (REACH), Official Journal text.
EUR-Lex, Directive 2011/65/EU on the restriction of the use of certain hazardous substances in electrical and electronic equipment, Official Journal text.