Offshore safety is organised around major accident hazards: loss of containment, fire, explosion, structural failure. Two ISO standards set the framework that every skid, panel and shelter on an installation has to fit.

ISO 17776

ISO 17776:2016, Petroleum and natural gas industries: offshore production installations, major accident hazard management during the design of new installations, describes how hazards are identified and assessed during design, how barriers (prevention, detection, control, mitigation, emergency response) are defined and how performance standards are set for the safety-critical elements that deliver them. It uses the bow-tie concept of threats, top event and consequences with barriers on both sides, and it requires that the design reflects the assessment: inherently safer options first, then engineered barriers with specified functionality, availability, reliability, survivability and interaction (FARSI).

ISO 13702

ISO 13702, Control and mitigation of fires and explosions on offshore production installations: requirements and guidelines (2015, with a 2024 edition now published), covers the fire and explosion strategy: layout and separation, hazardous-area classification and ventilation, control of ignition sources, fire and gas detection, emergency shutdown and depressurisation (blowdown), passive and active fire protection, explosion protection, escape and evacuation, and the performance standards for each. It is the standard behind fire and gas mapping, blowdown studies and the specification of fire-rated shelters and enclosures.

What an equipment package inherits

A package on an offshore installation will be asked to state: its hazardous-area certification (IEC 60079); its contribution to the inventory and the isolation and blowdown provisions (ESD valves, depressurising connections); its fire and gas detection interfaces; the fire rating or passive protection of any enclosure; the performance standard for any safety-critical element it contains (a HIPPS, a shutdown valve, a gas detector in a shelter); and the documentation that proves it. Analyser shelters, for example, carry gas detection, ventilation with pressurisation (Ex p) and an interface to the platform fire and gas system.

Our equipment

Analyser shelters, HIPPS, wellhead control panels and offshore-specified sampling systems are supplied with the certificates, interfaces and performance-standard documentation these frameworks call for; see also the IEC 60079 guide and the API RP 14C guide. All our standards guides.

Send your application, materials and the standards your contract names to mail@techincresearch.com or call +1 (289) 622-1032, and we will return a configuration, datasheet and quotation.

This article is our commentary on the standard's published scope, not a substitute for the standard itself; always work to the current edition named in your contract. Equipment specifications may change; performance depends on the application, how the equipment is used and operation in line with the operation manual.