Research Test Loops: How to Specify a High-Temperature Loop

At a glance. A research test loop circulates water, steam or another fluid at controlled temperature, pressure, flow and chemistry through a test section. Laboratories use loops to study corrosion, flow-accelerated corrosion, heat transfer and component behaviour under conditions close to those in power and process plants.
What a loop contains
Circulating pump, usually canned or magnetically coupled so there is no shaft seal to leak.
Heater, electric, sized for the heat-up rate and the losses at temperature.
Pressuriser, a vessel that sets and holds system pressure.
Test section, with flanged access for specimens and dense instrumentation.
Cooler and regenerative heat exchanger, to control temperature and save energy.
Water chemistry system, with sampling, conductivity and dissolved oxygen measurement and chemical dosing.
Controls, with interlocks, relief and data acquisition.
What to define before ordering
The test plan. What will be measured, on what specimens, for how long.
Conditions. Maximum temperature and pressure, flow rate and velocity in the test section.
Fluid and chemistry. Water quality, oxygen level, additives, or other fluids.
Materials. 316L for most water loops; nickel alloys for higher temperatures or aggressive chemistry.
Instrumentation. Number and type of temperature, pressure and flow points, and any special sensors.
Space and utilities. Power, cooling water and floor space, and whether the loop must be enclosed.
Safety
Pressurised hot water flashes to steam if released. Loops need relief valves, over-temperature trips, insulation, guarding and remote operation, and their design follows recognised pressure codes.
Where Tech Inc. equipment fits
Tech Inc. builds the high-temperature research test loop to each laboratory's test plan, together with sour-gas autoclaves, cylinder hydrostatic and pressure-cycling test benches and steam sampling systems.
Related reading
Sources
This guide is general information. Each loop is designed to the laboratory's requirements and the applicable pressure codes.