Process Note: Liquid Cooling Maintenance for Battery Energy Storage Systems

At a glance. Large battery energy storage systems (BESS) increasingly use liquid cooling: a water–glycol coolant circulates through cold plates under the cells and back to a chiller. Liquid cooling holds the cells in a narrower temperature band than air cooling, which slows degradation and evens out ageing across the system. The coolant loop needs the same care as any closed cooling system, and a leak inside a battery enclosure matters more than most. Operators and service companies across the world are building maintenance routines for the large fleets now being installed.
The cooling loop
Cold plates in each battery module or pack.
Manifolds and hoses in each rack or container.
Pump, expansion tank and filter in the thermal management unit.
Chiller or dry cooler, rejecting heat to air.
Sensors for temperature, pressure and flow, linked to the battery management system.
Commissioning and maintenance
Flushing of new loops to remove debris, oils and assembly residue.
Pressure testing to find leaks before coolant is added.
Filling with the specified premixed coolant, under vacuum or with a controlled fill that removes air.
Air removal, as trapped air causes hot spots, pump cavitation and noisy operation.
Routine checks of coolant level, pressure, flow and temperature differences.
Coolant testing: glycol concentration (freeze point), pH, inhibitor reserve, conductivity, appearance and particles.
Filter changes and, when the coolant has degraded, a drain, flush and refill.
Design points
Coolant specification from the system maker, including the glycol type and inhibitor package.
Materials compatibility across aluminium cold plates, copper, steels, elastomers and plastics.
Electrical safety, as coolant conductivity matters if a leak reaches live parts.
Service access to fill, drain and vent points in each container.
Climate: freeze protection on cold sites and cooling capacity on hot ones.
Waste handling, as used glycol coolant must be collected and disposed of under local rules.
Common problems
Leaks at quick-connects and hose joints.
Air locks after maintenance that starve some modules of flow.
Inhibitor depletion, which leads to corrosion of aluminium cold plates.
Mixing incompatible coolants during top-ups.
Blocked strainers from debris left after installation.
Where Tech Inc. equipment fits
Tech Inc. supplies the BESS coolant fill, flush and filtration cart, the flush-and-fill rig for liquid cooling loops, coolant treatment skids and strainer-air eliminators. For cell safety testing we also build the battery cell burst and vent pressure tester.